PP520 LED lighting controllers - User Manual
Set continuous mode
The output is set to continuous mode at a percentage of full
brightness:
RSc,s
Where:
c
output channel (1 or 2)
s
setting in percent (0 to 100)
Set switched mode
The output is set to continuous mode at a percentage of full
brightness:
RWc,s
Where:
c
output channel (1 or 2)
s
setting in percent (0 to 100)
Set pulse mode
The output can be set up to pulse on a trigger input. You can
configure the delay from the trigger to the start of the pulse, the
length of the pulse and the brightness.
An error is generated if the brightness setting requires a current
greater than 10A or if the combination of pulse width and setting is
not allowed.
RTc,p,d,s
Where:
c
output channel (1 or 2)
p
pulse width in milliseconds (0.02 to 999)
d
delay from trigger to pulse in milliseconds (0.02 to
999)
s
brightness setting in percent (0 to 999)
Set the trigger input
This command sets which input is used for pulse and switched
output modes.
RPc,p
Where:
c
output channel (1 or 2)
p
trigger input (1 or 2)
—
44
—