PP520 LED lighting controllers - User Manual
Report the version of firmware running in the PP520
VR
This command returns the firmware version. For example:
PP420 (HW001) V029
Disable keyboard
KBd,c
Where:
d
= 0 to enable the keyboard
= 1 to disable the keyboard
c
unlock code
In some applications it may be necessary to disable the keyboard so
that operation can only be controlled from the Ethernet port. This
command is cleared on a power cycle.
12.2
Lighting commands
Set the SafeSense mode
REc,m
Where:
c
output channel (1 or 2)
m
Bit 0 =
Bit 1 =
Bit 2 =
SafeSense mode:
0
: S flag set (prompt for current rating enabled)
1
: S flag cleared (prompt for current rating disabled)
0
: E flag set (error detection enabled)
1
: E flag cleared (error detection disabled)
0
: P flag set (positive triggers)
1
: P flag cleared (negative triggers)
Set the output current rating
This command changes the current rating for a light:
RRv,c
Where:
c
output channel (1 or 2)
v
rated current (10mA to 2A)
—
43
—