PP520 LED lighting controllers - User Manual
Enable Ethernet messages
GTm
Where:
m
= 0 to disable Ethernet messages
= 1 to enable Ethernet messages.
When Ethernet messages are enabled, any error reports are sent to
the most recent UDP or TCP address from which a command has
been received.
Messages are of the form:
Evtc,e
Where:
c
the channel number, or 0 for no channel
e
event value:
32 to 47 are lighting error codes
128 = light detected and waiting for current rating
129 = light detected and not waiting for current
rating.
Clear any errors
GR
If Ethernet messages are not enabled, the last event or error number
can be read by this command. Any error displayed on the unit is
cleared, so if there was a lighting error, the PP520 resumes auto-
sensing on that channel.
The reply is in he same form as the
GT
command above. If there are
no outstanding events or errors, only the prompt '
>
' is returned.
Clear settings
CL
Clears the output channel configuration. This excludes the Ethernet
settings. If the auto sense flag is set on any channel, then the flag and
the current rating are preserved.
Set/clear the webpage password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6
This command sets the password required to access the
webpages. If
EY
is entered on its own then the password is cleared.
There are six optional parameters, which are ASCII values for a
password from one to six letters. A value of 65 is ‘A’, 66 is ‘B’, etc to
90 is ‘Z’.
—
42
—