PP420 LED lighting controllers - User Manual
Where:
c
output channel (1 to 4)
s
setting in percent (0 to 100)
Set pulse mode
The output can be set up to pulse on a trigger input. You can
configure the delay from the trigger to the start of the pulse, the
length of the pulse and the brightness.
An error is generated if the brightness setting requires a current
greater than 10A or if the combination of pulse width and setting is
not allowed.
RTc,p,d,s
Where:
c
output channel (1 to 4)
p
pulse width in milliseconds (0.02 to 999)
d
delay from trigger to pulse in milliseconds (0.02 to
999)
s
brightness setting in percent (0 to 999)
Set the trigger input
This command sets which input is used for pulse and switched
output modes.
RPc,p
Where:
c
output channel (1 to 4)
p
trigger input (1 to 4)
Simulate an input trigger
This command simulates a trigger pulse. If the channel is in pulse
mode, it will pulse and show
PUL
in the display.
TRc
Where
c
= the input channel to be pulsed (1 to 4)
Set an internal trigger
This command enables or disables the internal trigger. When
enabled, all outputs are triggered simultaneously using an internal
trigger signal. This setting can be saved to non-volatile memory
using the
AW
command.
TT0
Disable the internal trigger
—
32
—