PP420 LED lighting controllers - User Manual
Save the settings to memory
AW
Once the settings are saved to memory, they are retained when the
unit is switched off. If this is not done, the changes to the settings are
volatile, and if the unit is switched off they revert to the settings in
force when the last
AW
command was issued.
Report the configuration
ST
The typical output is:
CH 1, MD 2, IP 4, CS 0.100A, SE 75.0, DL 2.0us, PU 300.0us, RT 500.0us, FL 1
CH 2, MD 0, IP 2, CS 0.100A, SE 25.8, DL 1.000ms, PU 1.000ms, RT 0.0us, FL 0
CH 3, MD 0, IP 1, CS 0.100A, SE 50.0, DL 1.000ms, PU 1.000ms, RT 6.000ms, FL 4
CH 4, MD 1, IP 4, CS 0.100A, SE 100.0, DL 100.0us, PU 1.000ms, RT 0.0us, FL 5
Where:
CH
Channel number
MD
Mode: 0 = continuous, 1 = pulse, 2 = switched
IP
Trigger input: 1, 2, 3, 4
CS
Current rating of the light
SE
Brightness percentage setting
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
ST0
Reports the general settings, The typical output is:
TM 1, TP 20.00m
This command reports the settings for a single channel.
STc
Where:
c
= Channel number (1 to 4)
—
29
—