![background image](http://html1.mh-extra.com/html/ganz/zn-l7210pha/zn-l7210pha_instruction-manual_3743671009.webp)
9
ENG-
The camera is designed for indoor operations. Choose a site for installation which
ensures that camera is exposed to neither extreme temperatures nor extreme
moisture or humidity. The ambient temperature must lie b5 and +40°C,
the relative humidity must not exceed 80%.
During operation, the unit generates a great deal of heat. Therefore ensure
sufficient ventilation and an adequate distance to heat-sensitive equipment or
objects.
Please observe the following installation conditions:
¾
Do not install the camera in the immediate vicinity of radiators or other sources of heat.
Avoid installing the camera where it is exposed to direct sunlight.
¾
Ensure sufficient space for laying the cables.
¾
Ensure adequate ventilation of the camera.
¾
For all cable connections, use only the suitable cables which also prevent any electrical
interference, where necessary.
¾
Ensure that the camera is not exposed to water at the installation site. If necessary, use
fresh desiccant in waterproof housing to avoid moisture due to condensation.
¾
Lay and install all cables in such a way that they cannot be damaged and ensure
sufficient strain relief.
¾
The installation always depends on the actual situation. No concrete instructions can
therefore be given here. The camera has a standard ¼” thread which can be installed
on both the top and bottom of the housing.
¾
Lay all cables up to the installation position.
¾
If necessary, connect a monitor with a coax cable (75 Ohm) to the BNC jack in order to
be able to check the video image on the spot.
¾
Connect the leads of the power supply unit to ter and – of the DC 12V
CONNECTOR. Pay attention to the correct connection of the leads.
Network connection
You can connect the camera via hub to a 10Base-T network. Use a standard UTP Category 5
with RJ45 connectors.
INSTALLATION