background image

 

01A.01 

 

 

22 

APPENDIX (D): HEXADECIMAL-DECIMAL 
CONVERSION TABLE 

Refer to the following table when you convert the MAC address of your device to IP address. 
 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

Hex 

Dec 

 

25 

37 

 

4A 

74 

 

6F 

111 

 

94 

148 

 

B9 

185 

 

DE 

222 

 

26 

38 

 

4B 

75 

 

70 

112 

 

95 

149 

 

BA 

186 

 

DF 

223 

 

27 

39 

 

4C 

76 

 

71 

113 

 

96 

150 

 

BB 

187 

 

E0 

224 

 

28 

40 

 

4D 

77 

 

72 

114 

 

97 

151 

 

BC 

188 

 

E1 

225 

 

29 

41 

 

4E 

78 

 

73 

115 

 

98 

152 

 

BD 

189 

 

E2 

226 

 

2A 

42 

 

4F 

79 

 

74 

116 

 

99 

153 

 

BE 

190 

 

E3 

227 

 

2B 

43 

 

50 

80 

 

75 

117 

 

9A 

154 

 

BF 

191 

 

E4 

228 

 

2C 

44 

 

51 

81 

 

76 

118 

 

9B 

155 

 

C0 

192 

 

E5 

229 

 

2D 

45 

 

52 

82 

 

77 

119 

 

9C 

156 

 

C1 

193 

 

E6 

230 

 

2E 

46 

 

53 

83 

 

78 

120 

 

9D 

157 

 

C2 

194 

 

E7 

231 

0A 

10 

 

2F 

47 

 

54 

84 

 

79 

121 

 

9E 

158 

 

C3 

195 

 

E8 

232 

0B 

11 

 

30 

48 

 

55 

85 

 

7A 

122 

 

9F 

159 

 

C4 

196 

 

E9 

233 

0C 

12 

 

31 

49 

 

56 

86 

 

7B 

123 

 

A0 

160 

 

C5 

197 

 

EA 

234 

0D 

13 

 

32 

50 

 

57 

87 

 

7C 

124 

 

A1 

161 

 

C6 

198 

 

EB 

235 

0E 

14 

 

33 

51 

 

58 

88 

 

7D 

125 

 

A2 

162 

 

C7 

199 

 

EC 

236 

0F 

15 

 

34 

52 

 

59 

89 

 

7E 

126 

 

A3 

163 

 

C8 

200 

 

ED 

237 

10 

16 

 

35 

53 

 

5A 

90 

 

7F 

127 

 

A4 

164 

 

C9 

201 

 

EE 

238 

11 

17 

 

36 

54 

 

5B 

91 

 

80 

128 

 

A5 

165 

 

CA 

202 

 

EF 

239 

12 

18 

 

37 

55 

 

5C 

92 

 

81 

129 

 

A6 

166 

 

CB 

203 

 

F0 

240 

13 

19 

 

38 

56 

 

5D 

93 

 

82 

130 

 

A7 

167 

 

CC 

204 

 

F1 

241 

14 

20 

 

39 

57 

 

5E 

94 

 

83 

131 

 

A8 

168 

 

CD 

205 

 

F2 

242 

15 

21 

 

3A 

58 

 

5F 

95 

 

84 

132 

 

A9 

169 

 

CE 

206 

 

F3 

243 

16 

22 

 

3B 

59 

 

60 

96 

 

85 

133 

 

AA 

170 

 

CF 

207 

 

F4 

244 

17 

23 

 

3C 

60 

 

61 

97 

 

86 

134 

 

AB 

171 

 

D0 

208 

 

F5 

245 

18 

24 

 

3D 

61 

 

62 

98 

 

87 

135 

 

AC 

172 

 

D1 

209 

 

F6 

246 

19 

25 

 

3E 

62 

 

63 

99 

 

88 

136 

 

AD 

173 

 

D2 

210 

 

F7 

247 

1A 

26 

 

3F 

63 

 

64 

100 

 

89 

137 

 

AE 

174 

 

D3 

211 

 

F8 

248 

1B 

27 

 

40 

64 

 

65 

101 

 

8A 

138 

 

AF 

175 

 

D4 

212 

 

F9 

249 

1C 

28 

 

41 

65 

 

66 

102 

 

8B 

139 

 

B0 

176 

 

D5 

213 

 

FA 

250 

1D 

29 

 

42 

66 

 

67 

103 

 

8C 

140 

 

B1 

177 

 

D6 

214 

 

FB 

251 

1E 

30 

 

43 

67 

 

68 

104 

 

8D 

141 

 

B2 

178 

 

D7 

215 

 

FC 

252 

1F 

31 

 

44 

68 

 

69 

105 

 

8E 

142 

 

B3 

179 

 

D8 

216 

 

FD 

253 

20 

32 

 

45 

69 

 

6A 

106 

 

8F 

143 

 

B4 

180 

 

D9 

217 

 

FE 

254 

21 

33 

 

46 

70 

 

6B 

107 

 

90 

144 

 

B5 

181 

 

DA 

218 

 

FF 

255 

22 

34 

 

47 

71 

 

6C 

108 

 

91 

145 

 

B6 

182 

 

DB 

219 

 

 

 

23 

35 

 

48 

72 

 

6D 

109 

 

92 

146 

 

B7 

183 

 

DC 

220 

 

 

 

24 

36 

 

49 

73 

 

6E 

110 

 

93 

147 

 

B8 

184 

 

DD 

221 

 

 

 

Содержание ZN-DNT352XE-MIR

Страница 1: ......

Страница 2: ... PERSONNEL FOR INTERNAL PARTS This symbol is intended to alert the user the presence of un insulated dangerous voltage within the product s enclosure which may be sufficient magnitude to constitute a electric shock risk to persons This symbol is intended to alert the user the presence of important operating and maintenance servicing instructions within the guide manual ...

Страница 3: ...Environment 13 6 1 2 Custom IP Environment 14 6 2 View video on web page 15 6 2 1 View video using IPAdmin Tool 16 6 3 Reset 17 6 4 Factory Default 17 APPENDIX A SPECIFICATIONS 18 Summary 18 Electrical Characteristics 19 Environment Condition 19 Mechanical Condition 19 APPENDIX B POWER OVER ETHERNET 20 PoE compatibility 20 Power classification 20 APPENDIX C DIMENSIONS 21 APPENDIX D HEXADECIMAL DEC...

Страница 4: ... and so on De interlacing on DSP Burnt in text supported Unicast Multicast supported Video Audio Video compression H 264 MPEG4 Planned for the future release MJPEG 25 30FPS 1080p PAL NTSC Audio compression G 711 µLaw aLaw PCM Analog video out for external monitors Video motion detection supported Two way mono audio supported Network RTSP HTTP protocol supported 10 100 Base T Ethernet Additional Fe...

Страница 5: ...a DC power adaptor DC Jack Cable 9 pin and 2 pin terminal block Video out cable Screws and anchors Installation template Hex wrench driver Quick installation guide Silicon waterproof band Clamping core To prevent electromagnetic interference Note i The above contents are subject to change without prior notice ...

Страница 6: ...tch Refer to 4 2 Setting the Lens Positions for more information on the switch Video output audio and IO terminal connector A 9 pin terminal block is included in the device package Connect this terminal block into this connector f or cable connection of video output audio input output and digital input output LAN connector RJ45 LAN connector for 10 100 Base T Ethernet Micro SD card slot Memory car...

Страница 7: ...locks into the holes 3 Place the waterproof silicon band on the bottom plate of the device and make it align with screw holes 4 Place the camera body to the installation surface and match three alignment holes with three anchor blocks Then tighten the surface anchor studs 5 Connect all the required cables to the camera 6 Adjust the lens position Detailed information can be found in 4 2 Setting the...

Страница 8: ...1 Installation Template Caution Installation template image s size scale in this installation guide is not 1 1 The correct size template design paper can be found inside the package separ ately tallation template ...

Страница 9: ...to a single direction as it is attached with the IR LED cable inside the dome 3 The figure and table below explains the lens switch settings 4 3 Setting the Image Attribute Through the camera s webpage users can configure image settings The camera image s brightness contrast saturation and sharpness are adjustable through the image settings Setup Video Audio Camera C Tilt the lens by vertically ad...

Страница 10: ...is installed properly streaming the images Sensor DI connection The camera provides 1 channel D I It can be connected to either a voltage type sensor or a relay type sensor as the following figures Settings can be done through the camera s webpage Input voltage range 0VDC minimum to 5VDC maximum Max 50mA Input voltage threshold 1 5V Mic Amp Speaker ETHERNET MICRO SD DO DI 1 Out Out 1 VIDEO C C In ...

Страница 11: ...lay rate Alarm DO connection Only the relay type is supported Relay Rating Max 24VDC 50mA Caution Do not exceed the maximum relay rating DO COM Relay Type Device Internal 3 3V DI COM DI COM Relay Type Voltage Type Output of Sensor Output of Sensor Internal Internal ...

Страница 12: ... connector for 10 100 Base T Ethernet Connect a LAN cable When the device is connected the orange LED stays on while green LED continues to blink 12V DC Power A 12 DC power connector is required for this device 12V Red Black Green LED Orange LED ...

Страница 13: ...may view the live streaming images on a web page using the device s default IP address 1 Convert the device s MAC address to the IP address Refer to the Hexadecimal Decimal Conversion Chart at the end of the manual The MAC address of the device is attached on the side or bottom of the device 2 Start the Microsoft Internet Explorer web browser and enter the address of the device 3 Web streaming and...

Страница 14: ...etwork area 1 Find the device from the IPAdminTool s list and highlight the device s name 2 Right click the mouse and select IP Address IP Setup window appears 3 In the IP Setup s window information under Local Network information displays the user PC s network area information Those information need to be incorporated to the IP Address Subnet Mask Gateway and DNS boxes except the last 2 sets of I...

Страница 15: ... streaming images through a web browser The default username and password is root pass 1 The browser asks to install the ActiveX Click Allow 2 Setup exe installation link or pop up window appears depends on Microsoft Internet Explorer version Proceed with rest of setup installation ...

Страница 16: ...oduct name IP address MAC address and etc IPAdminTool is provided with SDK at the following SDK path SDK root BIN TOOLS AdminTool 1 From the IPAdminTool s product list select the device by highlighting it 2 Right click the mouse and select web view 3 The system s default web browser opens the device s address Whether directly accessing the streaming video through typing IP address on a web page or...

Страница 17: ...ot 6 4 Factory Default 1 Push reset button and hold for 5 seconds 2 Release the Reset button when power LED blinks 3 Wait for the system to reboot The factory default settings can be inferred as follows IP address 192 168 xx yy Network mask 255 255 0 0 Gateway 192 168 0 1 User ID root Password pass ...

Страница 18: ... Streams Dual Stream Configurable Resolution 1920x1080 1280x720 800x450 480x270 320x180 Compression FPS Full frame 1080p Motion Detection Built in Burnt in Text Digital Video stream overlay text Output Analog video output for installation only Audio Input output 1 1 channel Compression Format G 711 Function Digital Input output 1 1 channel RS 485 Not supported Network 10 100 Base T Power over Ethe...

Страница 19: ...46mW Power 16 Ω D I Max 50mA 5VDC TTL level 4 5V threshold D O Max 500mA 24VAC or 1A 12VDC On state resistance 50 Ω max continuous Environment Condition Operating Temperature Operating Range DC12V 40 C 50 C 40 F 122 F PoE 0 C 50 C 32 F 122 F Cold Start DC12V 20 C 4 F PoE 0 C 32 F Operating Humidity Up to 85 RH Mechanical Condition Material Aluminum Die Casting Color White Dimension Housing 115 Ø x...

Страница 20: ... 140m and conform the PoE standard PoE compatibility With non Power Sourcing Equipment PSE When it is connected with non PSE the power adaptor should be connected With power adaptor Connecting both PSE and power adaptor does not do any harm to the product but power adaptor will be the only power source for the device as it has priority over PSE In this case disconnecting power adaptor while it is ...

Страница 21: ...01A 01 21 APPENDIX C DIMENSIONS Unit mm ...

Страница 22: ... 51 58 88 7D 125 A2 162 C7 199 EC 236 0F 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 7F 127 A4 164 C9 201 EE 238 11 17 36 54 5B 91 80 128 A5 165 CA 202 EF 239 12 18 37 55 5C 92 81 129 A6 166 CB 203 F0 240 13 19 38 56 5D 93 82 130 A7 167 CC 204 F1 241 14 20 39 57 5E 94 83 131 A8 168 CD 205 F2 242 15 21 3A 58 5F 95 84 132 A9 169 CE 206 F3 243 16 22 3B 59 60 96 85 133 AA 170 CF 207 F...

Страница 23: ...01A 01 23 REVISION HISTORY MAN DATE M D Y Comments 01A 01 05 10 2012 First release version ...

Отзывы: