![Ganz ZC-BNX4312NHA Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/ganz/zc-bnx4312nha/zc-bnx4312nha_instruction-manual_561058009.webp)
EG-9
Adjusting the line phase
(When using an AC24V 60Hz power source in the line lock
mode)
Use an AC power-source synchronization phase adjustment volume to
adjust the phase of power synchronization.
(The default position for the adjuster is fully turned to the left.)
Adjusting the DC iris level
Adjust the DC iris level to suit the environment in which you are using the
unit.
(The default position for the adjuster is in the center.)
Adjusting the view angle, focus and iris
Move the lever to adjust focus and angle of view.
Attention
●
When using the ZC-D5550NHA, adjust the focus when the dome cover
in place so that the axis of the lens goes passes through the center of the
dome cover, as in the illustration below.
Axis of the lens
Focus adjustment lever / View angle adjustment lever
DC iris level
adjustment volume
Line phase
adjustment volume
(US)ZC-D5000NTSC_0830.indd 9