background image

ZA-NVE40K Hardware Manual 

2010/2-1 D 

 19 

5. Fan Unit 

 

5.1. Description 

 

z

 

19” 1U rack mountable fan unit 

z

 

3 DC fans 

 

5.2. Unit view 

 

 

Figure 13. Fan unit 

 

Name 

Remarks 

Status LED 

Fan on & off 

DC Status Lamp 

In power switch 

DC Inlet 

DC power input terminal 

DC Outlet 

DC power output terminal 

 

Содержание ZA-NVE40K

Страница 1: ......

Страница 2: ...serting blades 11 Ejecting a blade 11 Inserting a blade 12 3 5 Factory Default Settings 12 3 6 Rebooting 13 4 Power Supplier Unit 14 4 1 Specifications 14 4 2 Unit view 14 4 3 Electrical characteristics 15 4 4 Environmental characteristics 16 4 5 Mechanical characteristics 16 4 6 Pin Description 17 4 7 Ejecting and inserting PSU 18 Ejecting a PSU 18 Inserting a PSU 18 5 Fan Unit 19 5 1 Description...

Страница 3: ...ient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not comp...

Страница 4: ...VE40K Hardware Manual 2010 2 1 D 4 CE COMPLIANCE This is A class product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures ...

Страница 5: ...osing Detect fan unit operation Self diagnosing Applied device ZN RS4000 series It is the blade version of ZN S4000 series ZN RS4000 series Main features High Quality Compression in real time streaming ZN RS4000 provides high quality MPEG 4 and MJPEG encoding at D1 in real time Network RTP RTSP and unicast multicast are supported Streaming support dual streaming mode such as different codec resolu...

Страница 6: ...utput 4 2 ch 2 5 mm Pitch Terminal Block Pluggable RS 232C RS 485 1 1 ea Connector Each slot Network 10 100 Base T Fan Unit 1 800 rpm x 3ea Temperature 0 o C 60 o C 32 o F 140 o F Humidity Upto 85 RH Dimension 482 6 W x 177 H x 322 D mm Weight 7 420 g Power Cable included 1 300 g ZN RS4000AE series x 10ea Table 1 Specification for ZA NVE40K 2 2 Power Consumption Minimum Including 1 x ZN RS4040AE V...

Страница 7: ...ZA NVE40K Hardware Manual 2010 2 1 D 7 2 3 Unit view Figure 1 GANZ encoder subrack ...

Страница 8: ...ork Reset Status 4CH Encoder Network Reset FAN FAN FAN Ethernet 1 USB 1 Ethernet 2 USB 2 Ethernet 3 USB 3 Ethernet 4 USB 4 Ethernet 5 USB 5 Ethernet 6 USB 6 Ethernet 7 USB 7 Ethernet 8 Ethernet 9 USB 9 Ethernet 10 USB 10 USB 8 Vin 1 1 Vin 1 2 Vin 1 3 Vin 1 4 Vin 2 1 Vin 2 2 Vin 2 3 Vin 2 4 Vin 3 1 Vin 3 2 Vin 3 3 Vin 3 4 Vin 4 1 Vin 4 2 Vin 4 3 Vin 4 4 Vin 5 1 Vin 5 2 Vin 5 3 Vin 5 4 Vin 6 1 Vin 6...

Страница 9: ...r view of subrack power cord ON 1 2 3 4 5 6 7 8 RACK ID Figure 5 Detailed rear view of subrack RACK ID 2 4 Mechanical characteristics Mechanical characteristics of subrack z Dimension Width inch 19 Height U 4 U Depth mm 288 mm PSU2 PSU1 0 I 0 I 110 220V 50 60Hz ...

Страница 10: ...onal Data Format PCM software compression G 711 uLaw Network 10 100 Base T De interlacing Supported by hardware Motion Detection Supported by hardware OSD Supported by hardware Video Stream Encryption AES Protocols SNTP DHCP UDP TCP RTP RTSP unicast multicast Parameters Min Typical Max Units Peak to peak amplitude 0 5 1 1 35 V Sync amplitude 143 286 386 mV Horizontal lock range 6 2 of line length ...

Страница 11: ...0 2 1 D 11 Figure 6 blade Figure 7 Front top side view of a blade 3 3 Mechanical characteristics Mechanical characteristics of a blade z Dimension Unit mm 30 1 W x 128 4 H x 220 D 3 4 Ejecting and inserting blades Ejecting a blade ...

Страница 12: ...dle of the blade and pull it up 4 Screw four collar screws 3 5 Factory Default Settings Factory default settings are as follows IP address 192 168 xx yy refer to 2 3 Serial Number MAC Address Mask 255 255 0 0 Gateway 192 168 0 1 User ID root Password pass MAC address 00 1C B8 C0 14 B1 IP address 192 168 35 69 Factory Default FD initialization procedure is as follows 1 Turn ON the power 2 Press Res...

Страница 13: ...Reset can be carried out as follows 1 Press Reset for 1 second When Reset function is activated Status LED and Network LED will blink together twice User may stop pressing Reset at this point 2 When Reset function has been completed LEDs will stop blinking ...

Страница 14: ...NVE40K Hardware Manual 2010 2 1 D 14 4 Power Supplier Unit 4 1 Specifications z AC DC Switched Mode Power Supplier Unit PSU z 19 3U Rack Mountable 10HP DC12V 150W 4 2 Unit view Figure 9 Power supplier unit ...

Страница 15: ...on 5 mV 96 Temperature Coefficient Less than 0 02 Over Current Protection 6 A 13 6 Over Voltage Protection 7 V 15 0 17 4 Hold up Time Typical 8 20ms Leakage Current 9 Less than 0 5mA 0 3mA Typical at 100VAC 0 5mA Typical at 230VAC NOTE 1 At 100 200VAC Ta 25 and maximum output power 2 At 100 240VAC 50 60Hz 3 Measure with JEITA RC 9131A probe Bandwidth of scope 100MHz 4 85 265VAC constant load 5 No ...

Страница 16: ...ewdrop Storage Temperature 30 85 Storage Humidity 10 95 RH No dewdrop NOTE 1 Load is percent of maximum output power or maximum output current whichever is greater 4 5 Mechanical characteristics z Construction Format 10HP x 3U compatible z Dimension Unit mm 50 8 W x 128 4 H x 236 D z Weight Unit g 812 z Cooling Free Air Convection DC OUT POWER Figure 10 Front top side view of PSU ...

Страница 17: ...tion z Mating Connector DIN61412 H15 Female Figure 11 Pin connection of PSU Pin Signal Name 4 6 Output 12V DC OUTPUT 8 Sense V 10 Sense 0V Assorted Signal 12 14 Output 0V DC OUTPUT 16 NC 18 NC 20 NC 22 NC 24 NC 26 NC 28 AC LINE 30 AC Neutral 32 FG AC INPUT ...

Страница 18: ...p the inject eject handle of the PSU and push it down as shown in below figure 3 Remove the PSU from the rack Figure 12 Ejecting a PSU Inserting a PSU 1 Make sure that the inject handle is in the outward position 2 Insert the PSU into the rack 3 Grasp the inject handle of the PSU and pull it up 4 Screw four collar screws ...

Страница 19: ...9 5 Fan Unit 5 1 Description z 19 1U rack mountable fan unit z 3 DC fans 5 2 Unit view Figure 13 Fan unit Name Remarks Status LED Fan on off DC Status Lamp In power switch DC Inlet DC power input terminal DC Outlet DC power output terminal ...

Страница 20: ...Voltage Operating Voltage V DC 6 13 8 Input Power W 3 60 Maximum Air Flow m3 min 0 63 x 3EA 1 89 At Average Value in Free Air Fan Speed min 1 1800 5 4 Environmental characteristics Parameter Value Operating 10 60 Allowable Ambient Temperature Range Storage 40 60 Expected Life 20 100 000 Hours Failure Rate 10 5 5 Mechanical characteristics ...

Страница 21: ...ZA NVE40K Hardware Manual 2010 2 1 D 21 Mechanical characteristics of fan unit z Dimension Width inch 19 Height U 1 U Depth mm 270 mm z Number of DC fans EA 3 ...

Отзывы: