Focal Length(mm)
1
2
3
4
5
6
7
8
CCD Size (in)
CCD Height(mm)
1/6“
1.73
82
47
32
24
20
16
14
12
1/4“
2.40
100
62
44
33
27
23
19
17
1/3.6“
3.00
113
74
53
41
33
28
24
21
1/3.2“
3.42
119
81
59
46
38
32
27
24
1/3“
3.60
122
84
62
48
40
33
29
25
1/2.7“
3.96
126
89
67
53
43
37
32
28
1/2“
4.80
135
100
77
62
51
44
38
33
1/1.8“
5.32
139
106
83
67
56
48
42
37
2/3“
6.60
118
95
79
67
58
50
45
1“
9.60
135
116
100
88
77
69
62
4/3“
13.50
132
119
107
97
88
80
Focal Length(mm)
9
10
15
20
30
40
50
CCD Size (in)
CCD Height(mm)
1/6“
1.73
11
10
7
1/4“
2.40
15
14
9
7
1/3.6“
3.00
19
12
11
9
6
1/3.2“
3.42
21
16
13
10
7
1/3“
3.60
23
20
14
10
7
5
1/2.7“
3.96
25
22
15
11
8
6
1/2“
4.80
30
27
18
14
9
7
5
1/1.8“
5.32
33
30
20
15
10
8
6
2/3“
6.60
40
37
25
19
13
9
8
1“
9.60
56
51
35
27
18
14
11
4/3“
13.50
74
68
48
37
25
19
15
• Enter the Camera Height.
If the camera height is known, then it can be entered. If the height in not known then it is recommended
to obtain an accurate reading otherwise estimate it based on known object heights in the scene.
Note
: A correct camera height measurement is required for accurate video analytics
• Enter the Cameras Tilt Angle.
If the tilt angle of the camera is known, then it can be entered. If the tilt angle is not known then
estimate it and use the mimics as a guide to confirm and change as required.
• Verify and change as required.
The objective is to ensure the mimics match people or other known objects in the scene, both the
height and angle of the mimic should represent the objects in the scene and adjustment of the height,
tilt and vertical field-of-view may be required to achieve this.
Click
Apply
to save your changes.
39
Ganz GXi Series
VCA Interface Manual v1.0.66
07.12.22
Page 40