GAT ECO.Lock 7xxx F/ISO 

 

2             

HB_GAT-ECOLock-7xxxFISO--EN_12  

 

 

www.gantner.com

 

  Copyright 2017-

2018 

by GANTNER Electronic GmbH, Schruns (Austria). 

Operating instructions, manuals and software are protected by copyright. All rights are reserved. Copying, duplication, translation, 
installation in any electronic medium or machine-readable form in whole or in part is prohibited. The sole exception is represented 
by creation of a back-up copy of software for own use as a safeguard, so far as this is technically possible and recommended by 
us. Any infringement will render the party committing such infringement liable to compensation payment. 
 

Liability 

Any claims against the manufacturer based on the hardware or software products described in this manual shall depend 
exclusively on the conditions of the guarantee. Any further-reaching claims are excluded, and in particular the manufacturer 
accepts no liability for the completeness or accuracy of the contents of this manual. The right is reserved to make alterations, and 
alterations may be made at any time without prior notice being given. 
 

Trademarks 

Attention is drawn at this point to markings and registered trademarks used in this manual. All product and company names, which 
are mentioned in this manual, are only used for identification and explanation purposes. Some of these names may be trademarks 
or registered trademarks of the corresponding company. 
 

Contact 

The contact information for questions regarding this product or for general enquiries is listed below: 
 

Contact address of manufacturer: 

GANTNER Electronic GmbH 

 

Montafonerstrasse 8 
6780 Schruns, Austria 

 

Phone: 

+43 5556 73784 - 0  

 

Fax: 

+43 5556 73784 - 8020 

 

 

Email: 

[email protected]   

 

Website: 

www.gantner.com   

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

Содержание Mifare Gat ECO.Lock 7 F/ISO Series

Страница 1: ...AT ECOLock 7xxxFISO EN_12 1 GAT ECO Lock 7xxx F ISO Battery Powered Electronic Lock MIFARE and ISO 15693 Installation Configuration Operation Document Version 1 2 Installation Configuration Operation...

Страница 2: ...pend exclusively on the conditions of the guarantee Any further reaching claims are excluded and in particular the manufacturer accepts no liability for the completeness or accuracy of the contents of...

Страница 3: ...e installation commissioning and servicing of our products must be performed by suitably trained personnel In particular electrical connections must only be made by correspondingly qualified specialis...

Страница 4: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Страница 5: ...Hole 18 3 7 2 Measurements for the Button Drill Hole 19 3 7 3 Installation Instructions for Non Metallic Doors 20 3 8 Installation in Lockers with Metallic Doors 21 3 8 1 Measurements for the Button D...

Страница 6: ...figuration Settings 43 6 4 Upload Configuration Settings to the GAT ECO Lock 7xxx F ISO 44 6 5 Configuration Settings of the GAT ECO Lock 7xxx F ISO 45 6 5 1 Operating Mode 45 6 5 2 Locker Number 45 6...

Страница 7: ...required to maintain the locker system and the LED signaling are also explained in this section In chapter 6 CONFIGURATION you will find information on how to configure the GAT ECO Lock 7xxx F ISO us...

Страница 8: ...function critical information is displayed in this manual using the following formatting with sample text These instructions must be read and followed NOTE This signal word is used to indicate importa...

Страница 9: ...oftware The lock can operate in one of five operating modes thereby providing flexibility for different locking requirements within a facility Using a locker To use a locker the user closes the door o...

Страница 10: ...echnology the device supports B LEGIC F MIFARE ISO ISO 15693 The GAT ECO Lock 7xxx F ISO can operate with data carriers using MIFARE and ISO 15693 technologies It is necessary for all devices and data...

Страница 11: ...lockers For outdoor lockers ext temp range IP 64 For metallic lockers Figure 2 1 Components of the GAT ECO Lock 7xxx F ISO system 1 GAT ECO Lock 7100 F ISO 2 GAT ECO Lock 7100 NW F ISO 3 GAT ECO Lock...

Страница 12: ...200 Adapter Part No 614322 Adapter for GAT ECO Lock 7100 to cover a 38 mm drilling in metal doors No screws required 6 GAT ECO Basic Set F ISO Part No 812528 Accessory set for configuring and maintain...

Страница 13: ...SO EN_12 13 2 5 GAT ECO Lock 7xxx F ISO Dimensions and Components Non metallic door Metallic door 1 Battery cover 4 LED ring 2 Locking bolt 5 Lock electronics 3 Button 6 Booster Figure 2 2 GAT ECO Loc...

Страница 14: ...and unlocks as required ideally using a data carrier of the same type to be used with the locker system to ensure that the data carrier functions as required 3 2 Replacement after a Burglary Attempt I...

Страница 15: ...O Lock 7xxx F ISO is suitable for locker doors with a maximum door leaf thickness of 28 mm 1 1 When installing the GAT ECO Lock 7xxx F ISO into lockers with narrow doors ensure that the lock housing d...

Страница 16: ...ght hinged door Left hinged door Figure 3 2 Locker door hinge definition left right The position of the locking bolt and button of the GAT ECO Lock 7xxx F ISO is different for right and left hinged do...

Страница 17: ...e GAT ECO Lock 7xxx F ISO to suit a right or left hinged locker door can be carried out easily by completing the following steps Lift the lock electronics out of the lock housing Rotate the lock elect...

Страница 18: ...lling all locks in a new locker system a test installation of one lock into a completed locker and a function check must be performed See section 3 1 Test Installation 3 7 1 Measurements for the Butto...

Страница 19: ...imum door leaf thickness of 28 mm 1 1 For locker doors that do not adhere to these measurements or for doors with an unfixed pivot point depending on the type of hinge used the distance between the lo...

Страница 20: ...before the GAT ECO Lock 7xxx F ISO See 3 10 Door Handle Installation Optional for more information Mount the GAT ECO Lock 7xxx F ISO onto the inside locker door using 4 screws Hardware recommendation...

Страница 21: ...talling all locks in a new locker system a test installation of one lock into a completed locker and a function check must be performed See section 3 1 Test Installation 3 8 1 Measurements for the But...

Страница 22: ...door it is recommended to install the lock a corresponding distance away from the locker door e g using a mounting bracket as shown below in Figure 3 9 This installation method allows the lock to be...

Страница 23: ...surements in Figure 3 8 and Figure 3 5 for right hinged doors or Figure 3 6 for left hinged doors If you are also using the optional GAT Lock Door Handle this must be installed before the GAT ECO Lock...

Страница 24: ...inged door GANTNER provides the following labels Frontfolie GAT Lock 6010 GANTNER o Nr Part No 666834 Self adhesive locker door label in GANTNER design without numbering Frontfolie GAT Lock 6010 GANTN...

Страница 25: ...ll the GAT Lock Door Handle On the door outer side drill 4 blind holes 2 diameter 8 mm and depth 9 mm around the lock button hole according to the measurements in Figure 3 12 On the door inner side dr...

Страница 26: ...ounted onto the door inner side The installation instructions for metallic or non metallic doors are provided in the previous chapters 1 GAT Lock Door Handle 2 GAT ECO Lock 7xxx F ISO 3 GAT ECO Lock 7...

Страница 27: ...The GAT ECO Lock 7xxxx F ISO indicates a weak battery state with five red flashes of the LED ring and five acoustic signals during a locking attempt NOTE For optimal battery lifespan use the approved...

Страница 28: ...n the lock has already been used and the batteries are being replaced the lock must be activated using the battery cover key see 4 1 3 Replacing the Batteries Press the lock button in using the batter...

Страница 29: ...the battery cover key 4 2 USB Connection A Micro B USB port is located on the opposite side of the GAT ECO Lock 7xxx F ISO to the locking bolt The USB port location on the side of the lock allows con...

Страница 30: ...y are available on the Leisure Software USB stick which is included in the GAT ECO Basic Set F ISO The LED ring flashes alternating red green after connecting to the computer To activate configuration...

Страница 31: ...ing a data carrier which is done by pressing the button completely in 5 2 Operating Modes The GAT ECO Lock 7xxx F ISO can function in one of the following operating modes Free locker with or without d...

Страница 32: ...ded the data carrier can no longer unlock the locker In this case the user must recode their data carrier at a central station e g a GAT Info 6800 F with additional coding license Part No 193732 The d...

Страница 33: ...e locker cannot be opened anymore In this case the data carrier must be reset at a central station Release the locker door 5 2 2 Free Locker Universal Mode Free locker universal operating mode differs...

Страница 34: ...the same authorization access e g family cards The data carriers are authorized for use with the personal locker using the program data carrier included in the GAT ECO Basic Set F ISO see section 5 3...

Страница 35: ...3 times and the GAT ECO Lock 7xxx F ISO switches off o All data carriers are now deleted from the GAT ECO Lock 7xxx F ISO and no longer have the authorization to use the locker any more 5 2 5 Persona...

Страница 36: ...ed in the lock The previously authorized data carriers are no longer authorized to use the locker 4 has the same index value and a newer valid to date than in the lock o The index value and the new va...

Страница 37: ...emergency opening of the corresponding locker can be carried out using a master data carrier Three master data carriers are included in the basic set and they are only valid for the respective system...

Страница 38: ...the battery data carrier is used See section 4 1 3 Replacing the Batteries for more information After replacing the batteries of a GAT ECO Lock 7xxx F ISO in personal locker mode all settings stored i...

Страница 39: ...the following lock states are signaled by the status LED LED Ring Meaning Blue flash Lock ready to read a data carrier Red flash No authorization Error Green flash Data carrier accepted Operation succ...

Страница 40: ...GAT ECO Lock 7xxx F ISO Operation 40 HB_GAT ECOLock 7xxxFISO EN_12 www gantner com...

Страница 41: ...ng Modes Free locker Sector number of the data on the data carrier and the time setting for the duration of use function Date and time set automatically Unique numbers of the master data carriers The...

Страница 42: ...ure 6 1 to find an existing project Alternatively click on the Create Project icon 2 in Figure 6 1 to start a new project Figure 6 1 GAT Config Manager Project setup Once a project is established loca...

Страница 43: ...nnected GAT ECO Lock 7xxx F ISO has been added to the Devices directory you can now view and adjust the lock configuration settings Complete the following steps to view the configuration settings Sele...

Страница 44: ...7xxx F ISO When you are finished configuring the GAT ECO Lock 7xxx F ISO settings in GAT Config Manager it is important to finalize the configuration by uploading the file to the GAT ECO Lock 7xxx F I...

Страница 45: ...programming card Personal locker expiry date or Free locker unique number 6 5 2 Locker Number The number of the locker where the GAT ECO Lock 7xxx F ISO is installed can be defined The locker number...

Страница 46: ...select the PreLock Personal Locker option to turn the function on off 6 5 6 RF Standards The GAT ECO Lock 7xxx F ISO can operate with data carriers that use ISO 15693 and ISO 14443A MIFARE technology...

Страница 47: ...er that locked it see 5 2 5 Personal Locker Expiry Date Mode Boolean False Free Locker Use TimeLimit Select the type of time limit for the locker see 5 2 1 Free Locker Mode with or without Duration of...

Страница 48: ...egment where general data is stored Integer 13 Certificate Block Num The segment where certificate data is stored Integer 15 Locker Block Num The segment where locker data is stored Integer 19 Gantner...

Страница 49: ...ing Field Reader type MIFARE supported types MIFARE Classic 1k and 4k MIFARE Ultralight DESFire EV1 and EV2 ISO 15693 Note It is recommended to have customer specific data carriers approved by GANTNER...

Страница 50: ...pability DIN 4547 2 class C 7 7 Environmental Conditions Permitted ambient temperature Indoor model 0 C to 55 C 32 F to 131 F Outdoor model 25 C to 55 C 13 F to 131 F Protection type Indoor model IP 5...

Страница 51: ......

Страница 52: ...ntner com info syx nl info aus gantner com London UK Bochum Deutschland Los Angeles USA T 44 178 249 9195 T 49 234 58896 0 T 1 844 703 1139 info syxautomations co uk info de gantner com info us gantne...