5.4
Dust suction is not correct.
- Check the ventilator, in the case that it is damaged, replace it.
- Check the condition of the filter, if necessary replace.
- Filter is blocked: vibrate for 5 -10 seconds.
- Check the condition and position of the sweeping seals, e.g. check the seal in the brush area
   and if necessary replace it.
- Check that the dirt container is seated correctly.

5.5
Dirt is not swept from the floor.
- Lower the side brush.
- The dirt container is full: empty it.
- Check condition and position of the sweeping seals if necessary replace it.
- Check the condition of the main brush and side brush, if necessary replace then.
- Batteries are empty - load immediately them.

5.6
Machine does not drive forwards.
- Check that the drive belts are fitted correctly.
- The drive belts are torn: fit new ones.
- Motor does not run (see point 5.1).

6. Servicing and maintenance:

6.1
Before any cleaning or servicing work is carried out on the machine and before any parts are replaced,
the following precautions must be taken: the machine plug must be removed from the battery socket, the
key must be removed from the key switch and the hand brake must be applied so as to make sure that
the machine cannot be set in motion inadvertently.

- 8 -

Содержание 75 P

Страница 1: ...ng dusts hazardous to health and the following specific limitations should be noted in particular Machine models with the designation G Unsuitable for removing dusts of carcinogenic substances of the...

Страница 2: ...key from the key switch 1 7 When leaving the machine the operator should move the hand brake thus ensuring that it cannot move whilst he is away 1 8 When using the machine the operator should take car...

Страница 3: ...odify design features of your machine thereby rendering it less safe to operate from both the active and the passive point of view The manufacturer does not accept any liability for damage occurring a...

Страница 4: ...s follows the blocking mechanism on the top of the driving wheel should be pressed with the foot Thus the radial and axial braking are released and the machine is ready to move 3 4 Starting the machin...

Страница 5: ...e brush receives light pressure it will automatically move inwards and on removal of the pressure will return to the wider position 4 3 By means of the vacuum generated above the dirt container the du...

Страница 6: ...lap must be allowed to close to re establish the suction to the inner area 4 7 After some sweeping time how long depends upon the type of dirt that is being swept it is recommended to empty the dirt c...

Страница 7: ...tional errors and how to rectify them 5 1 Motor does not run Tank is empty fill with petrol Batteries are empty load immediately the BEM shows the red light Battery connector is not connected Check th...

Страница 8: ...ping seals if necessary replace it Check the condition of the main brush and side brush if necessary replace then Batteries are empty load immediately them 5 6 Machine does not drive forwards Check th...

Страница 9: ...st sealed the control panel function to be OK 6 5 The ventilator of the vacuum motor must be cleaned regularly especially when used in connection with very fine dust 6 6 The dirt container must be cle...

Страница 10: ...urface 1 9 m Air circulation approx 10 m min The detected weighted acceleration value is less 2 5 m s acc to ENV 25349 The sound pressure level is measured according to MRL postscript 1 point 1 7 4 f...

Отзывы: