background image

 

 

Operating Instruction

 

Machine model
Sweeper 75 P

1. Important warnings:

1.1 Important!
This machine is not suitable for removing dusts hazardous to health and the following specific limitations
should be noted in particular: Machine models with the designation G: Unsuitable for removing dusts of
carcinogenic substances of the group I, II, III1, dusts containing pathogens and dusts classified under
explosive dust categories St 1 and St 2 in Zone 11.

- 1 -

Содержание 75 P

Страница 1: ...ng dusts hazardous to health and the following specific limitations should be noted in particular Machine models with the designation G Unsuitable for removing dusts of carcinogenic substances of the...

Страница 2: ...key from the key switch 1 7 When leaving the machine the operator should move the hand brake thus ensuring that it cannot move whilst he is away 1 8 When using the machine the operator should take car...

Страница 3: ...odify design features of your machine thereby rendering it less safe to operate from both the active and the passive point of view The manufacturer does not accept any liability for damage occurring a...

Страница 4: ...s follows the blocking mechanism on the top of the driving wheel should be pressed with the foot Thus the radial and axial braking are released and the machine is ready to move 3 4 Starting the machin...

Страница 5: ...e brush receives light pressure it will automatically move inwards and on removal of the pressure will return to the wider position 4 3 By means of the vacuum generated above the dirt container the du...

Страница 6: ...lap must be allowed to close to re establish the suction to the inner area 4 7 After some sweeping time how long depends upon the type of dirt that is being swept it is recommended to empty the dirt c...

Страница 7: ...tional errors and how to rectify them 5 1 Motor does not run Tank is empty fill with petrol Batteries are empty load immediately the BEM shows the red light Battery connector is not connected Check th...

Страница 8: ...ping seals if necessary replace it Check the condition of the main brush and side brush if necessary replace then Batteries are empty load immediately them 5 6 Machine does not drive forwards Check th...

Страница 9: ...st sealed the control panel function to be OK 6 5 The ventilator of the vacuum motor must be cleaned regularly especially when used in connection with very fine dust 6 6 The dirt container must be cle...

Страница 10: ...urface 1 9 m Air circulation approx 10 m min The detected weighted acceleration value is less 2 5 m s acc to ENV 25349 The sound pressure level is measured according to MRL postscript 1 point 1 7 4 f...

Отзывы: