background image

STRONG. SIMPLE. COMPACT.

Rev Date 23 0610

800.285.6780   [email protected]

EDGE

 INSTALLATION MANUAL PAGE 9

COLORWASH INSTALLED OPTION

Control Board

• 

The required connections to the PDT Board are installed at the factory. 

• 

A Reset Button is located on this board next to the ethernet port J1. 

• 

Ethernet Network connectivity to ethernet port J1 is required to adjust the settings stored on the controller.

Network Connectivity

In order to configure the ColorWash portion 
of your EDGE system, it must have a 
connection to the internet. The connection 
is made using the RJ45 connection port on 
the control board. This ethernet connection 
must have access to outside networks. 
The network cannot be restricted to local 
connections only. Enterprise networks may 
block outgoing connections using a firewall. 
If this is the case, the following ports must 
be opened for outbound connections to 
allow the device to connect to our servers:

User Interface

• 

In order to access the ColorWash system, you will need to create an account on the ColorWash dashboard 
at https://dashboard.colorwash.app. 

• 

Requests for new accounts can also be sent to our support team at [email protected] or (800)-285-6780. 
You will need to provide our team with a valid email address. An invitation link from colorwash@colorwash.
app will be sent to that email. Click the Create Account button to access the registration form.

• 

After your account has been created, you can access the dashboard and adjust the settings for your system.

• 

For information about configuring your system using the dashboard,  please refer to the ColorWash 
Dashboard User Guide. This can be found on the G&G website at www.ggled.net.

QUESTIONS?

Please contact G&G Support at 800.285.6780

Port

TCP

UDP

Usage

31314

Initial device-server connection

993

Fall-back device-server connection #1

443

Fall-back device-server connection #2

80

Fetch device firmware

Содержание EDGE

Страница 1: ...azard if left unchecked This heating can also serve as an ignition source for gasses generated by the corrosion of metals inside of the enclosure Regularly scheduled inspections are recommended to ens...

Страница 2: ...es Fixtures 2 Leader Cable s 3 Jumper Cable s 4 Termination Plug s 5 Mounting Brackets Ceiling or Wall 6 G G EDGE Power Data Translator PDT Includes controls power distribution and drivers 1 EDGE Stan...

Страница 3: ...U fixtures in each string have 4 pin connectors THRU fixtures have a gray connector shell on the input end and a black connector shell on the output end while LEAD fixtures have black connector shells...

Страница 4: ...ds using a chalk line or laser to mark the mounting bracket locations 2 4 and 6 fixtures require at least two mounting brackets Brackets should be installed near the ends of the fixtures 8 models requ...

Страница 5: ...D at the bottom of the board below the driver fuses The input circuit shall be supplied with a 20A breaker on 120V systems or a 15A breaker on 277V systems Power Data Translator PDT Board The AC Input...

Страница 6: ...The B outputs 1B and 2B have a limit of 40 feet G G recommends that the split be as even as possible within these limits For example if possible split 88 feet into a 48 foot string and a 40 foot stri...

Страница 7: ...be connected to output 2A Failure to make the correct connections will lead to lighting effects being generated in an erratic manner To connect the leader cables to the LED Output terminals remove 2 3...

Страница 8: ...ee discrete wires in the data cable these are marked on the board next to the terminals D D and COM Optionally the RJ45 8P8C connector can be used instead of the three terminals if the DMX source supp...

Страница 9: ...be opened for outbound connections to allow the device to connect to our servers User Interface In order to access the ColorWash system you will need to create an account on the ColorWash dashboard a...

Отзывы: