DMX CONFIGURATION

If the ColorWash option is installed, please skip this section and proceed to the Control Board and Network 
Connectivity sections on page 9.

Data Input

• 

The DMX connections bring fixture data into the 

EDGE

 PDT board and optionally pass the data along to 

other DMX devices. 

• 

Terminal blocks are provided for connecting the three discrete wires in the data cable; these are marked on 
the board next to the terminals (D+, D-, and COM).

• 

Optionally, the RJ45 (8P8C) connector can be used instead of the three terminals if the DMX source 
supports this type of cabling.  (XLR-to-RJ45 adapters are available from electronics distributors like 
Newark.)

• 

A DMX terminator switch is provided on the PDT board. It is set to terminated at the factory. Move this 
switch to its other position if termination is not required. An indicator for the termination being active 
is provided near the termination switch.  DMX Installation is now complete.  Disregard the 

ColorWash 

Installed Option

 section next.

Содержание EDGE

Страница 1: ...azard if left unchecked This heating can also serve as an ignition source for gasses generated by the corrosion of metals inside of the enclosure Regularly scheduled inspections are recommended to ens...

Страница 2: ...es Fixtures 2 Leader Cable s 3 Jumper Cable s 4 Termination Plug s 5 Mounting Brackets Ceiling or Wall 6 G G EDGE Power Data Translator PDT Includes controls power distribution and drivers 1 EDGE Stan...

Страница 3: ...U fixtures in each string have 4 pin connectors THRU fixtures have a gray connector shell on the input end and a black connector shell on the output end while LEAD fixtures have black connector shells...

Страница 4: ...ds using a chalk line or laser to mark the mounting bracket locations 2 4 and 6 fixtures require at least two mounting brackets Brackets should be installed near the ends of the fixtures 8 models requ...

Страница 5: ...D at the bottom of the board below the driver fuses The input circuit shall be supplied with a 20A breaker on 120V systems or a 15A breaker on 277V systems Power Data Translator PDT Board The AC Input...

Страница 6: ...The B outputs 1B and 2B have a limit of 40 feet G G recommends that the split be as even as possible within these limits For example if possible split 88 feet into a 48 foot string and a 40 foot stri...

Страница 7: ...be connected to output 2A Failure to make the correct connections will lead to lighting effects being generated in an erratic manner To connect the leader cables to the LED Output terminals remove 2 3...

Страница 8: ...ee discrete wires in the data cable these are marked on the board next to the terminals D D and COM Optionally the RJ45 8P8C connector can be used instead of the three terminals if the DMX source supp...

Страница 9: ...be opened for outbound connections to allow the device to connect to our servers User Interface In order to access the ColorWash system you will need to create an account on the ColorWash dashboard a...

Отзывы: