Installation
12
· DVI-FiberLink
Preparation
1. Install the master matrix switch of the
DVICenter
series.
2. Install the user module you want to connect to the matrix switch using the
DVI-FiberLink
expansion.
Since the expansion modules later connect the user module to the matrix switch,
the user module does not need to be connected at this moment.
Installing the expansion module for the matrix switch
Place the first expansion module close to the matrix switch.
Transmission CAT:
Use a CAT5 (or better) twisted pair cable to connect this interface to
a
Dynamic Port
in the
CON
mode of the matrix switch.
Transmission – Tx:
Insert the LC plug of the fibre optics, which is available as acces-
sory. Connect the other end of the cable to the
Transmission – Rx
interface of the
receiver module.
Transmission – Rx:
Insert the LC plug of the fibre optics, which is available as acces-
sory. Connect the other end of the cable to the
Transmission – Tx
interface of the
receiver module.
Power In:
Connect the external power pack or the
power loop
cable, which is connected
to another expansion module, to this interface.
Power Loop:
If the external power pack is to supply power to another expansion mod-
ule, connect an optional power loop cable to this interface.
NOTE:
Detailed information regarding the power supply with power loop cables is
given on page 14.
Содержание DVI-FiberLink
Страница 25: ... Deutsch ...
Страница 49: ... English ...
Страница 50: ... ...
Страница 51: ... English ...