Basic configuration of the KVM-over-IP™ connection
G&D ControlCenter-IP 2.0 ·
19
English
5. Enter your setting in the paragraph
UID locking
:
6. Click on
Save
.
UID locking:
Only the remote stations specified in the list may estab-
lish a KVM-over-IP connection (
Enabled
), or all remote
stations may establish a connection (
Disabled
).
Connected device
UIDs:
If UID locking is switched on, activate the
Permitted
slider
in the line of each device that is allowed to establish a
connection to the IP matrix switch.
Add target module:
Click this button and enter the UID of the target module
that is allowed to connect to this IP matrix switch. Click
on
Save
.
Add console module:
Click this button and enter the UID of the console mod-
ule that is allowed to connect to this IP matrix switch.
Click on
Save
.
Remove:
Click on a permitted target module or a permitted con-
sole module and then on
Remove
to revoke the permis-
sion.