Содержание FPT-DACR-GW

Страница 1: ...06472 203 484 7161 FAX 203 484 7118 www gamewell fci com FocalPoint System Utilities User s Guide FocalPoint Receivers Gateway Installation Operation Manual Copyright 2009 All Rights Reserved Publishe...

Страница 2: ...n which the Authority Having Jurisdiction requires If you do not know which authority has jurisdiction in your area contact your local fire department or building inspector for guidance It is importan...

Страница 3: ...ards and applicable state and local codes At a minimum the requirements of Chapter 7 of NFPA the National Fire Alarm Code shall be followed A preventative maintenance agreement should be arranged thro...

Страница 4: ...on and recommend a solution Smoke detectors cannot be expected to provide adequate warning of a fire caused by arson children playing with matches especially in bedrooms smoking in bed violent explosi...

Страница 5: ...e IDs 13 2 3 Radionics D6600 Setup 14 2 3 1 D6600 Description 14 Figure 2 2 Radionics D6600 Receiver Application Example 14 2 3 2 Supported Formats 14 2 3 3 D6600 Serial Communication Connection 15 Fi...

Страница 6: ...munication Configuration 24 3 4 1 Establish Receivers Gateway Workstation Communication 24 3 4 2 Receivers Gateway s Port Configuration 25 Section 4 Receivers Gateway Reference Information 27 4 1 Layo...

Страница 7: ...Gateway is capable of monitoring up to 20 digital alarm receivers Supported receiver types are ADEMCO 685 Radionics D6600 Silent Knight 9500 9800 Teldat VisorALARM Supported protocols for these receiv...

Страница 8: ...t is intended to be installed in accordance with the following regulatory agencies FocalPoint Receiver Gateway Ethernet Digital Alarm Receiver Telephone Dialer FocalPoint Components Ethernet FACP NOTE...

Страница 9: ...Part I Safety Standard for Electrical Installations 1 4 Environmental Requirements This product must be installed in the following environmental conditions Temperature range of 0 C to 49 C 32 F 120 F...

Страница 10: ...About Receivers Gateways Related Documentation 10 FocalPoint Receivers Gateway Installation Operation Manual P N 53251 Rev A 9 8 09...

Страница 11: ...g units Every device that calls a receiver must have an account code that uses a supported protocol Each account code must be unique throughout the entire system Each device or panel must utilize the...

Страница 12: ...there is a DIP switch set the switches as Switch 4 PRN OFF PRN Off Switch 8 OFF COM OFF Off 2 2 4 685 Supported Formats The supported address format is ADEMCO Contact ID 2 2 5 685 Parallel Printer Req...

Страница 13: ...the native format or be very similar In all cases field tests should be performed to confirm the reported format of panel devices 2 2 9 685 Site IDs When using dialers to communicate with the 685 rec...

Страница 14: ...rouble event information that can be used in conjunction with a Workstation and other FocalPoint clients The Radionics D6600 receiver is a modular multi format digital receiver designed to receive dis...

Страница 15: ...fer to the table below for D6600 settings For more detailed information see the Radionics D6600 Program Entry Guide Workstation Receivers Gateway D6600 Unused COM Port COM DB9 connector to non dedicat...

Страница 16: ...hen the D6600 is OK The D6600 knows that the Receivers Gateway is OK if it received the Gateway s reply to the message that it sent 2 3 6 D6600 Operation and Event Handling Device Addresses as Reporte...

Страница 17: ...es on page 11 2 4 1 9500 9800 Cable Configuration Use the following figure to configure the serial cable running from the automation port of the receiver to a non dedicated COM port of the PC on which...

Страница 18: ...iver sites are supervised by the Workstation Panels connected to receivers generate a periodic test message The Receivers Gateway uses that test message to supervise the site In the Gateway s configur...

Страница 19: ...l devices reported by Silent Knight 9500 9800 receivers to fit the FocalPoint system format of an 8 character point ID Since there is no actual node or sub node located at the panel the Gateway always...

Страница 20: ...tion computer Figure 2 5 VisorALARM Cable Connections 2 5 2 VisorALARM Serial Communication Connection The VisorALARM also connects via an Ethernet cable into the intranet where it can receive events...

Страница 21: ...sing and Supervision Receivers Gateway monitors the VisorALARM for trouble conditions and reports them to connected Workstations The Workstation will auto create an icon for this receiver and will dis...

Страница 22: ...Digital Receivers Installation and Configuration Teldat VisorALARM Receiver Setup 22 FocalPoint Receivers Gateway Installation Operation Manual P N 53251 Rev A 9 8 09...

Страница 23: ...tings Refer to Receivers Gateway Network Communication Configuration on page 24 System Limitations Each instance of the Receivers Gateway can support a maximum of 20 receivers 3 2 Workstation Startup...

Страница 24: ...curity Profiles 3 3 1 Closing and Shutting Down the Gateway File Close will minimize the Receivers Gateway screen the Receivers Gateway is still running and its icon appears in the System Tray File Sh...

Страница 25: ...pe in the Gateway s IP Address Select a gateway from the list of Online Gateways Step 8 Click on the OK button Step 9 Exit the Configuration Tool and respond to the confirmation window prompt Yes mean...

Страница 26: ...Receivers Gateway Installation and Configuration Receivers Gateway Network Communication Configuration 26 FocalPoint Receivers Gateway Installation Operation Manual P N 53251 Rev A 9 8 09...

Страница 27: ...s will be reported to the Workstation and appear in the Events Box like any other FocalPoint system event Refer to the FocalPoint Workstation manual for details concerning the Events Box and event han...

Страница 28: ...ies Monitoring FPT Receivers Gateway The FPT Receivers Gateway window displays Step 2 From its menu select File Login The User Login window displays Step 3 Click on to highlight a user name that has a...

Страница 29: ...RAM OK Report as event Program Exit on device PROG with device type Processor X 47 REMOTE SOFTWARE PROGRAM IN Report as event Program Entry on device PROG with device type Processor X 48 REMOTE SOFTWA...

Страница 30: ...port as event Offline Restored on device AUDIO LINE with device type Audio System X 62 DATA ERROR LINE Report as event Advise on device E62 L LINE with device type Telephone X 62 NO DATA RECEIVED LINE...

Страница 31: ...NTERCEPT Report as event Device Re enabled on device C900INTR with device type Communication X 82 C900 SWITCHED TO FALLBACK Report as event Device Disabled on device C900INTR with device type Communic...

Страница 32: ...e type Communication X 75 NO RESPONSE TO ACK Report as event Advise on device EVENT 75 with device type Communication X 76 MESSAGE UNKNOWN Report as event Advise on device EVENT 76 with device type Co...

Страница 33: ...e Detector Smoke 112 ZONE G ZO GROUP Combo Detector Combustion 113 ZONE G ZO GROUP Waterflow Water flow 114 ZONE G ZO GROUP Heat Detector Heat 115 ZONE G ZO GROUP Pullstation Pull Station 116 ZONE G Z...

Страница 34: ...urg 151 ZONE G ZO GROUP Gas Leak Detector Gas detected 152 ZONE G ZO GROUP Leak Detector Refrigeration 153 ZONE G ZO GROUP Heat Detector Loss of heat 154 ZONE G ZO GROUP Waterflow Water Leakage 155 ZO...

Страница 35: ...Power Supply Power Supply Overcurrent 313 SRVC G SR GROUP Zone Engineer Reset User 314 ACPWR G AC GROUP Power Supply Primary Power Supply Failure 320 RELAY G RE GROUP Audible Output Sounder Relay 321...

Страница 36: ...ault 354 COMM G CO GROUP Communication Fail to communicate 355 RFSUP G RF GROUP Communication Loss of radio supervision 356 RFPOL G RF GROUP Communication Loss of central polling 357 ZONE G ZO GROUP P...

Страница 37: ...GROUP Control Panel Primary Receiver Active 397 COMM G CO GROUP Communication Primary Receiver Down 398 DACR G DA GROUP Control Panel Backup Receiver Active 399 DACR G DA GROUP Control Panel Receiver...

Страница 38: ...O GROUP Zone Access threat level change 432 ZONE G ZO GROUP Zone Access relay trigger fail 433 ZONE G ZO GROUP Zone Access RTE shunt 434 ZONE G ZO GROUP Zone Access DSM shunt 435 ZONE G ZO GROUP Door...

Страница 39: ...eneric Control Output Reversing relay disable 526 NAC3 G NA GROUP Common Bell Output Notification Appliance Ckt 3 disable 527 NAC4 G NA GROUP Common Bell Output Notification Appliance Ckt 4 disable 53...

Страница 40: ...616 ZONE G ZO GROUP Zone Service Request 621 ZONE G ZO GROUP Zone Event Log reset 622 ZONE G ZO GROUP Control Panel Event Log 50 full 623 ZONE G ZO GROUP Control Panel Event Log 90 full 624 PANEL G P...

Страница 41: ...ZO GROUP Control Panel System Inactivity 900 ZONE G ZO GROUP Control Panel Download Abort 901 ZONE G ZO GROUP Control Panel Download Start 902 ZONE G ZO GROUP Control Panel Download Interrupt 910 ZON...

Страница 42: ...Contact ID Reporting Formats 42 FocalPoint Receivers Gateway Installation Operation Manual P N 53251 Rev A 9 8 09...

Страница 43: ...way System Architecture 7 H Help 28 About 28 I Installation Environmental Conditions 9 L Login 28 N Network Clients 28 R Radionics D6600 Receiver 14 D6600 Configuration 15 Device IDs 16 Event Handling...

Страница 44: ...Index 44 FocalPoint Receivers Gateway Installation Operation Manual P N 53251 Rev A 9 8 09...

Страница 45: ...ECT TO THE PRODUCTS TRADEMARKS PROGRAMS AND SERVICES RENDERED BY MANUFACTURER INCLUDING WITHOUT LIMITATION INFRINGEMENT TITLE MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE MANUFACTURER SHALL N...

Страница 46: ...Gamewell FCI 12 Clintonville Road Northford CT 06472 1610 USA 203 484 7161 fax 203 484 7118 www gamewell fci com...