3
Version 1, 21 August 2019, 3 of 21
4.1 TECHNICAL DATA
Inlet
½” BSP – Female
Outlet
Flow Straightener
Headwork
Thermostatic mixing valve
Mains Powered (Transformer)
Input
90
– 264V - 47/63Hz 0.15A
Output
6.75V DC
– 0.5A
Cable length
0.7m
Battery Powered
N/A
Solenoid
Input Voltage
6.75V DC
Power Consumption
-
Cable length
3.2m
Connection
Inlet
3/ ” BSP - Female
Outlet
3/ ” BSP - Male
Pressure Range
(kPa)
Min
30
Max
1000
Temperature (°C)
Min
5
Max
80
Finish
Chrome
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without
notice.
Table 1. Technical information
4.2 SENSOR DETAILS
•
Hardware
Varox 4.2.2
•
Software
IQ7VARIR2V 7.15-0256, release 15.5.2015
•
Input Voltage
6.75V DC
– 0.5A
•
Cable length
3.2m
•
Sensor function
Standard washbasin (with proximity sensor)
•
Preset line purge feature interval:
12 hours after last flush, water flow duration 3 min
•
Preset continuous run:
5 min
•
Sensor range:
Sensor1 and Sensor2 custom made steps
5.0
WATER SUPPLY CONDITIONS
5.1 INTRODUCTION
This progressive sequential thermostatic mixer with proximity sensor is manufactured to the highest
standards and has approval to AS4032.4 which permits it to be installed in healthcare establishments such
as hospitals, nursing homes and residential care homes. When installed in healthcare establishments the
supply conditions detailed in Table 2 must be observed and the commissioning and servicing requirements
detailed on section 6 & 8 must be followed.
5.2 SUPPLY PRESSURE REQUIREMENTS
This mixer is designed to be installed on all types of plumbing systems.
Hot and cold water supply pressures should be reasonably balanced; however, the mixer will function within
specification on unequal pressures up to 10:1.