INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOOD MODEL HIDE
230-240 Vac - 50 Hz
To set the timer to zero keep the button T4 pressed with the aspirator switched off, otherwise
the timer will remain set on 120 hour functioning and the reminder will occur again when the
hood is switched off again.
Exhausting cooker hood. The equipment is constructed in accordance with European
Standards and with the requirements included in the following Directives: 2006/95EC ( Low
Voltage Directive), 2004/108 (Electromagnetic Compatibility).
Always disconnect the hood from the mains before carrying out any maintenance or cleaning
operation
Read the instruction manual before installing and/or using the hood .
In order that the minimum distance between the supporting surface for the cooking pots on
gas hob and low-voltage components present in the hood is at least 65cm as required by the
regulations in force, it is necessary that the lower part of the hood is at least 60cm away from
the work top.
If the mounting instructions of the gas cooker indicate a wider distance, respect it. The unit
must not be mounted above cookers fitted with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes produced by gas-
fed equipments or fuel-fed equipments (this does not apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together with other gas-fed
or fuel-fed equipments.
For an easy access, it is advisable to move possible furniture under the installation area.
For mounting the hood follow the illustrations in
Fig. 1
.
To remove the bottom panel follow the illustrations on
Fig. 2
To install the cover follow illustrations on
Fig. 3
In order to remove the remaining glue or any impurity, the cooker hood must be cleaned
immediately after installation and after having removed the protective film.
The cooker hood must be cleaned frequently both internally and externally (at least once a
month).
Do not let dirt gather on the inner and outer surfaces of the hood.
To clean the exterior of the hood do not use either acid or basic products, or abrasive
sponges.
Clean the hood with a sponge dampen in warm water and a little quantity of neutral detergent
(for example dishwasher detergent), in order to remove possible particles of grease.
Rinse with a damp cloth, removing all the detergent carefully, following the satin finish
direction on the steel surface.
Drying is very important, especially in areas where water is particularly hard and leaves
limestone.
Particular attention should be paid to the
metallic anti-grease filters
that are designed to
trap particles of fat contained in the fumes. The metallic anti-grease filters must be washed at
least once a month with detergent in hot water (or in the dish-washer).
ATTENTION: the grease collected in the filters can easily catch fire and it is therefore
extremely important to clean the metallic filters on a regular basis as per instructions.
This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1)
Using a standard plug to be connected to the power cable and inserted in a mains
socket which must be accessible (so that the plug can be disconnected when servicing
is carried out). Make sure that the plug is accessible also after the complete installation
of the equipment.
By means of a fixed mains connection, fitting a bipolar switch, which ensures the
disconnection, with an opening distance of the contacts allowing a complete
disconnection on the conditions of the overvoltage III category, according to installation
regulations. The ground connection (yellow-green wire) must not be interrupted.
The
charcoal filters
are designed to collect unpleasant odours in the cooking fumes. The air
is then released purified in the environment. The charcoal filters must not be washed, but
replaced 2 or 3 times a year, depending on how much the hood is used. New filters are to be
requested directly to the manufacturer. In order to replace the activated charcoal filters, you
should remove the anti-grease filters. Your are then to take off the activated charcoal filters
placed at the two sides of the aspirator. Turn the filters until they unfasten from aspirator
(Fig.
7)
. Invert the operation in order to install the new charcoal filters.
2)
Refer to the plate inside the hood for the mains voltage and frequency ratings.
The hood features a LED light that, in addition to offering a good lighting and a significant
energy savings, are guaranteed to last on average 10 times more than traditional lights. For
replacement, contact the Assistance Service.).
This cooker hood can be employed as exhausting or filtering.
Exhausting
(
Fig. 4
). The carbon filters should not be installed on the hood in exhausting
version.
Kitchen smokes are driven outside through a flue joined to the exhaust pipe flue connector..
Pipes must be communicating with the exterior of the house. The diameter of the outlet of the
hood is 150mm. A 150-125 reduction is provided with the hood.
This pipe must not under any circumstances be connected to cooker, boiler or burner exhaust
pipes, etc.
Filtering
(
Fig. 5
). The fumes pass through the carbon filters to be purified and recycled into
the kitchen through a pipe connected to the outlet of the hood up to the hole in the top of the
cabinet. This hole must be free and communicating with the kitchen.
In the filtering version you must install the two carbon filters on the sides of the aspirator. To
install the carbon filters you must first remove the metal grease filters (
Fig. 6
) and then install
carbon filters by turning them counterclockwise (
Fig. 7
).
The present instruction manual is an integral part of the appliance itself, therefore it must be
carefully kept and ALWAYS accompany it, even in case of its assignment to another owner or
user or in case the cooker hood is moved to another installation plant.
Any eventual adjustment to the electrical system, which may be necessary to install the
cooker hood, must be carried out only by competent people. Any repair carried out by no
competent people may cause damages. For any repair or needed technical action make
reference to a Technical Assistance Center, which is authorized to carry out the replacement
of the spare parts.
Always make sure that all the electrical parts (lights, exhaustion unit) are disconnected when
the appliance is not in use.
By storms take off the main switch of the house electrical system.
The using of the cooker hood must not be other than the use of exhausting units for cooking
damps on domestic kitchens. The manufacturer does not accept any liability for damages
caused by people, animals or things, by installation and maintenance mistakes or by any
illegitimate use.
Make sure that the voltage (V) and the frequency (Hz) ratings indicated on the plate inside
the cooker hood correspond to the ones available in the installation place.
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at higher speeds only
when there is a heavy build-up of fumes or odours.
Ideally, the hood should be switched on as soon as cooking is started and then kept on until
all odours have been eliminated.
The controls consist of these commands
.
Press
TL
to turn on the light, press
T1
to swich on
the hood at first speed and to switch off the aspirator, press
T2-T3-T4
to select functioning
speeds.
By pressing of the command T1 the motor starts running at the 1
st
speed. The commands
T2-T3-T4 switch the motor on respectively at the 2
nd
, 3
rd
and 4
th
speed. In order to switch
the motor off press T1 once if set at the 1
st
speed, twice if set at the 2
nd
, 3
rd
and 4
th
speed
With the button T4, select the maximum speed of the extraction fan for 5 minutes (button
blinking), after which the extraction fan will automatically switch to the 3rd speed.
We remind that the use of products functioning with electrical energy implies the observance
of some essential security rules, as follows:
•
This equipment is not intended for people (children included) with reduced mental or
motor capacities, with lack of experience or knowledge, unless they are supervised or
unless a person responsible for their security, gives them instructions regarding the
use of the equipment. Children must be supervised in order to be sure that they do not
play with the equipment.
Any cleaning action is forbidden if the appliance hasn’t been disconnected from the
main power supply and if the main switch of the house electrical system is not off. If
cleaning is not carried out according to these instructions, a fire may break out.
Do not pull, take off or twist the cable coming out from the appliance, even though this
has been disconnected from the main power supply.
Do not sprinkle or throw any water directly on the appliance.
Do not stick any sharp tool inside the exhausting holes and into the air discharge.
Do not take out the filters in order to reach the internal sides of the appliance in case
the main switch of the house electrical system is not off.
Do not singe or flambé directly underneath the cooker hood. Take particular care when
frying to ensure that the oil does not catch fire.
•
•
•
•
•
•
Adjustable and delayed self switching off
While the hood is working, keep the TL command pressed until all leds start blinking.
By pressing one of the commands (T1, T2, T3, T4) you can program the delayed self
switching off, as follows:
T1
corresponds to 5 minutes
T2
corresponds to 10 minutes
T3
corresponds to 15 minutes
T4
corresponds to 20 minutes
During the time of the self switching you can go any change the set speed.If you
select the maximum speed, after 5 minutes the extraction fan switches to the 3rd
speed and will automatically turn off at such speed. .
Filters maintenance reminder
Aluminium anti-grease filters
Once the hood is switched off, after 30 hour functioning, all the leds of the speed buttons
switch on with a fixed light for 30 seconds to remind that aluminium anti-grease filter need
cleaning.To set the timer to zero keep the button T4 pressed with the aspirator switched off,
otherwise the timer will remain set on 30 hour functioning and the reminder will occur again
when the hood is switched off again.
Charcoal filter (for filtering hoods)
Once the hood is switched off, after 120 hour functioning, all leds blink for 30 seconds to
remind that the charcoal filter need cleaning.
OPERATION
WARNINGS
USE
ELECTRICAL CONNECTIONS
INSTALLATION
MAINTENANCE
GB
Содержание HIDE
Страница 1: ...HIDE 230 Vac 50 Hz 3953333 ...
Страница 8: ... Fig 1 l ...
Страница 9: ...A2 A1 Magnets c Fig 2 ...
Страница 10: ...no 2 V T TC M4x1O l o 1 l no 3 V T Z GR NATE M4x17 ___ Ciì Fig 3 ...
Страница 11: ...Fig 4 Fig 5 Fig 6 Fig 7 ...