Operation and Installation Manual
19
1.4. Operating principle
Operation as a heat pump:
Air temperature
Cold water temperature
Heating time
Mean power consumption
+35°C
+10°C
6,5 h
427 W
+20°C
+10°C
7,5 h
375 W
+7°C
+10°C
10,0 h
265 W
Table of the time to heat a 200 l DHW to 55°C.
The heat pump can be operated with the DHW tank connected directly or via a either directly or via a heat coil with a minimum heat exchange area of 1 m
2
.
If connected directly to the DHW tank, install a DHW-certified circulation pump.
Before commissioning the heat pump, connect the DHW tank and bleed air from the DHW system with the vent valve located at the top of
the heat pump housing.
In accordance with Regulation (EU) No. 517/2014 and Regulation (EU) No. 2015/2068, this unit is an equipment/product which contains or
the operation of which depends on CFC (chlorofluorocarbon) greenhouse gas. The refrigerant circuit is hermetically sealed.
1.5. Heat pump technical data
Specification
unit
Small
Catalogue number
-
09-240201
COP (A20/W10-55)
1
-
2,6
Application range
°C
+7
÷
+35
Maximum DHW temperature
°C
55
Coolant:
-
R 134 a / 600 g
Dimensions (H × W × D)
mm
660 × 680 × 400
Weight
kg
36
Supply voltage
V
230
Water piping connections
”
¾ GZ
Condensate drain connection
mm
12
Heat pump nominal power consumption
W
375
Operating pressure
bar
6
Mean heating capacity
kW
2
Recommended DHW tank capacity
l
100
÷
250
Sound power level
2
dB
61
Sound pressure level
3
dB
50
Electrical protection rating
-
C16
Nominal air flow rate
m
3
/h
261
Compressor
-
rotary
1
PN-EN 16147.
2
EN 12102.
3
At a distance of 2 m.