background image

Installation and Operating Manual / Warranty Card - SGW(S), SGW(S)B, SG(S) 

© All rights reserved - Galmet Sp. z o.o. Sp. K.

8

5. Technical specification

5.1. Technical specification of the SGW(S): Mini Tower (100-140), Tower (200-500), Big Tower (700-1500)

Specification

Unit

SGW(S) Mini Tower

SGW(S) Tower

SGW(S) Big Tower

100

120

140

200

250

300

400

500

700

1000

1500

Storage capacity 

1

l

102

114

129

197

247

309

405

513

694

1005

1433

Nominal capacity

l

106

120

136

210

262

322

420

523

705

1019

1442

Tank's max. working temp.

°C

95

95

95

95

95

95

95

95

95

95

95

Coil's max. working temp.

°C

110

110

110

110

110

110

110

110

110

110

110

Tank's max. working pressure

MPa

0,6

0,6

0,6

1,0

1,0

1,0

1,0

1,0

1,0

1,0

1,0

Coil's max. working pressure

MPa

0,6

0,6

0,6

1,6

1,6

1,6

1,6

1,6

1,6

1,6

1,6

Coil surface

m

2

0,6

0,95

0,95

1,4

1,4

1,4

1,8

2,0

2,4

2,7

2,7

Coil power (70/10/45°C)

kW

16

23

23

33,6

33,6

33,6

43

48

57,6

64,8

64,8

Levelling feet

-

yes

yes

yes

yes

yes

yes

yes

yes

no

no

no

Bimetal thermometer

-

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

yes

Magnesium 

anode

5/4" plug 

3

25x390 25x390 25x390 38x400 38x400 38x400 38x400 38x600 38x600 38x600 38x600

M8 screw

-

-

-

38x200 38x200 38x200 38x200 38x200 38x200 38x400 38x400

Efficiency

l/h

390

560

560

800

800

800

1030

1150

1380

1580

1580

Connections for the SGW(S) 100-400, 700, 1000 water heaters

h1 - Cold water inlet

G" / mm ¾ / 210 ¾ / 165 ¾ / 165 1 / 210 1 / 210 1 / 130 1 / 240

-

6

4

 / 215

6

4

 / 250

-

h2 - CH water outflow

G" / mm ¾ / 310 ¾ / 250 ¾ / 250 1 / 290 1 / 285 1 / 280 1 / 320

-

1 / 375 1 / 450

-

h3 - Sensor cover

G" / mm R 

3

 / 400 R 

3

 / 375 R 

3

 / 375 R 

3

 / 435 R 

3

 / 440 R 

3

 / 435 R 

3

 / 570

-

3

 / 575 R 

3

 / 590

-

crk - Circulation

G" / mm ¾ / 500 ¾ / 450 ¾ / 450 ¾ / 680 ¾ / 600 ¾ / 650 ¾ / 770

-

5

4

 / 925

5

4

 / 875

-

h4 - CH hot water inflow

G" / mm ¾ / 710 ¾ / 750 ¾ / 750 1 / 790 1 / 755 1 / 750 1 / 870

-

1 / 1045 1 / 1000

-

h5 - DHW outflow

G" / mm ¾ / 790 ¾ / 920 ¾ / 1070 1 / 860 1 / 1085 1 / 1355 1 / 1470

-

6

4

 / 1715

6

4

 / 1570

-

Connections for the SGW(S) 500, 1500 water heaters

h1 - Cold water inlet

G" / mm

-

-

-

-

-

-

-

1 / 180

-

-

6

4

 / 250

h2 - CH water outflow

G" / mm

-

-

-

-

-

-

-

1 / 320

-

-

1 / 450

h3 - Sensor cover

G" / mm

-

-

-

-

-

-

-

3

 / 530

-

-

3

 / 600

h4 - CH hot water inflow

G" / mm

-

-

-

-

-

-

-

1 / 970

-

-

1 / 1000

crk - Circulation

G" / mm

-

-

-

-

-

-

-

¾ / 1320

-

-

5

4

 / 1630

h5 - DHW outflow

G" / mm

-

-

-

-

-

-

-

1 / 1650

-

-

6

4

 / 2250

Dimensions

Coupler for an electrical set

G"

5/4

5/4

5/4

6/4

6/4

6/4

6/4

6/4

6/4

6/4

6/4

Inspection hole

Ø

-

-

-

180/120 180/120 180/120 180/120 180/120 280/205 280/205 280/205

d - Internal diameter

Ø

400

400

400

550

550

550

600

630

700

900

900

D - External diameter

Ø

518

518

518

670

670

670

700/800

2

755/840

2

855/860

2

1055/1060

2

1100

2

L - Height with insulation

mm

1020

1120

1270

1100

1300

1615

1750

1950

2050/2080

2

1960/1990

2

2650/2680

2

Weight (empty)

kg

55

60

65

84

108

118

137

157

260

415

540

1

  In accordance with the Commission Regulation (UE) 812/2013, 814/2013

2

  Detachable Neodul insulation

3

  Capacities 700, 1000 and 1500 l - magnesium anode plug 2"

Содержание SGW(S) Mini Tower 100

Страница 1: ...S Tower vertical SGW S BigTower vertical SGW S BTowerBiwal vertical SG S vertical SGW S horizontal Type Cover Colour Spiral coils 100 120 140 200 250 300 400 500 700 800 1000 1500 skay artificial lea...

Страница 2: ...heme of the SGW S Tower Slim 200 300 11 5 6 Technical specification of the SGW S Tower Slim 800 1000 12 5 7 Scheme of the SGW S Tower Slim 800 1000 13 5 8 Technical specification of the SGW S BTower B...

Страница 3: ...tom on the heels of 5 4 200 500 l 2 700 1500 l Heaters are equipped with additional connections 3 4 capacity 100 140 l and 1 capacity 200 1500 l where you can install the drain valve In the SGW S B 20...

Страница 4: ...The hose should be heat resistant up to 80 C with internal diameter of9mmandmax lengthof1 2m runtoadrainwithadowngrade min 3 inanenvironmentoftemperaturenotlowerthan0 C Thehosemustbe protected against...

Страница 5: ...s housing Ks water outlet drain C circulation GE connection for the heating element W S spiral coil Tr thermometer Cz sensor cover 2 2 Exemplary connection scheme of the water heater in an closed sys...

Страница 6: ...n the heating module 230V electrical scheme heater 2 3 kW grz grz grz L1 L2 L3 A1 A2 A3 B1 B2 B3 2 N PE 3 4 1 400V electrical scheme heater 4 5 9 kW 400V electrical scheme heater 12 24 kW 3 Troublesho...

Страница 7: ...the electronic part and the anode is connected incorrectly Lack of contact between the ground tank and the electrical part of the anode The anode is contacted with the mass of the tank Fill the tank...

Страница 8: ...Connections for the SGW S 100 400 700 1000 water heaters h1 Coldwaterinlet G mm 210 165 165 1 210 1 210 1 130 1 240 6 4 215 6 4 250 h2 CHwateroutflow G mm 310 250 250 1 290 1 285 1 280 1 320 1 375 1...

Страница 9: ...Warranty Card SGW S SGW S B SG S 9 5 3 Scheme of the SGW S MiniTower 100 140 Tower 200 500 BigTower 700 1500 crk h3 h2 h1 h5 h4 SGW S 100 140 SGW S 200 250 400 crk h3 h2 h1 h5 h4 crk h3 h2 h1 h5 h4 SG...

Страница 10: ...0 38x400 M8 screw 38x200 38x200 38x200 Connections for the SGW S Tower Slim 200 water heaters h1 Cold water inlet G mm 1 140 h2 CH water outflow G mm 1 225 h3 Sensor cover G mm 325 h4 Circulation G mm...

Страница 11: ...o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 11 5 5 Scheme of the SGW S Tower Slim 200 300 h1 L h2 h3 h4 h5 h6 h1 L h2 h3 h4 h5 h6 SGW S Tower Slim 200 I SGW S Tower Slim...

Страница 12: ...MPa 1 6 1 6 Coil surface m2 2 4 3 7 Coil power 70 10 45 C kW 44 5 60 Efficiency l h 1099 1468 Magnesium anode 2 plug 38x600 38x600 5 4 plug 38x400 38x400 Connections h1 Cold water inlet G mm 6 4 210...

Страница 13: ...rights reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 13 5 7 Scheme of the SGW S Tower Slim 800 1000 SGW S Tower Slim 800 1000 5 Technical specificat...

Страница 14: ...1 375 1 450 h3 Sensor cover I G mm R 3 8 355 R 3 8 400 R 3 8 435 R 3 8 570 R 3 8 575 R 3 8 590 crk Circulation G mm 450 595 650 770 5 4 925 5 4 880 h4 Hot water inflow from solar collector G mm 1 550...

Страница 15: ...ating Manual Warranty Card SGW S SGW S B SG S 15 5 9 Scheme of the SGW S BTower Biwal 200 1500 crk h3 h2 h1 h5 h6 h7 h8 h4 crk h3 h2 h1 h5 h6 h7 h8 h4 SGW S B 200 300 700 1000 SGW S B 250 400 SGW S B...

Страница 16: ...W 24 24 43 48 Additional source coil s power 70 10 45 C kW 24 24 24 24 Dimensions h1 Cold water inlet G mm 1 130 1 130 1 160 1 160 h2 Coil return I G mm 1 210 1 180 1 240 1 240 h3 Coil return II G mm...

Страница 17: ...BTower Biwal Max 200 500 with two spiral coils at the bottom part of the tank d D h7 h5 h3 h2 0 h4 h6 L h8 h9 d D h7 h5 h3 h2 h1 0 h4 h6 L h8 h9 SGW S BTower Biwal Max 200 with two spiral coils at th...

Страница 18: ...SGW S BTower Biwal Slim 200 water heaters h1 Cold water inlet G mm 1 140 h2 Water outflow to solar collector G mm 1 225 h3 Sensor cover I G mm 325 h4 Circulation G mm 1 485 h5 Hot water inflow from so...

Страница 19: ...and Operating Manual Warranty Card SGW S SGW S B SG S 19 5 13 Scheme of the SGW S BTower Biwal Slim 200 300 h1 L h2 h3 h4 h5 h6 h7 h8 h9 h1 L h2 h3 h4 h5 h6 h7 h8 h9 SGW S BTower Biwal Slim 200 I SGW...

Страница 20: ...CH coil s surface m2 1 2 1 8 CH coil s power 70 10 45 C kW 24 5 39 CH coil s efficiency l h 600 958 Magnesium anode 2 plug 38x600 38x600 5 4 plug 38x400 38x400 Connections h1 Cold water inlet G mm 6...

Страница 21: ...reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 21 5 15 Scheme of the SGW S BTower Biwal Slim 800 1000 SGW S BTower Biwal Slim 800 1000 5 Technical sp...

Страница 22: ...570 h6 DHW outflow Gw 3 4 mm 790 920 1070 Connections for the SG S 200 400 tanks h1 Water drain Gw 1 mm 130 160 h2 Cold water inlet Gw 1 mm 210 240 h3 Sensor cover I Gw 1 2 mm 440 570 h4 Sensor cover...

Страница 23: ...reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 23 5 17 Scheme of the SG S 100 500 SG S 100 140 SG S 200 400 SG S 300 500 h1 h2 h3 h4 h5 5 Technical sp...

Страница 24: ...plug 38x200 38x400 38x400 Connections h1 Cold water inlet Gw 6 4 mm 250 270 270 h2 Additional source inlet Gw 6 4 mm 360 380 380 h3 Sensor cover I Gw 1 2 mm 650 600 600 h4 Additional source inlet Gw 6...

Страница 25: ...All rights reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 25 5 19 Scheme of the SG S 700 1500 SG S 700 1500 5 Technical specification...

Страница 26: ...45 C kW 23 24 24 Efficiency l h 560 570 570 Coil power 80 10 45 C kW 30 4 32 32 Efficiency l h 740 760 760 Demand for heating water from CH boiler m3 h 2 6 2 9 2 9 Magnesium anode 5 4 plug 25x390 38x2...

Страница 27: ...w ownica spi Typ Jedn SGW S poziomy 140 S pozi Pojemno l 140 Max ci nienie pracy zbiornika MPa Max ci nienie w ownicy MPa Pow wymiennika do c o m2 0 95 Moc wymiennika do c o 70 10 450 C kW 23 Wydajno...

Страница 28: ...W The wall thickness of the jackets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thi...

Страница 29: ...l as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thickness SGW S MiniTower 100 400 2 0 S235JR 2 2 S235JR SGW S...

Страница 30: ...ets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thickness SGW S BTower Biwal Slim 2...

Страница 31: ...Tower Slim ErP class C 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identifier SGW S SLIM 200 SGW S SLIM 250 SGW S SLIM 300 3 EN Energy efficiency class C C C 4 EN Standing loss W 7...

Страница 32: ...A A 4 EN Standing loss W 42 46 48 5 EN Storage volume L 199 240 286 7 8 SGW S BTower Biwal Max 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identifier SGW S Bd 200 SGW S Bd 300 SGW...

Страница 33: ...leddirectlyinfrontoftheheateronthepipesupplyingitwithcoldwater Onlyvalvesacceptablebyadequateorgansshould beused adjustedtostoragewaterheaters Safetyvalveshouldbeusedaccordingtotheoperatingmanualforth...

Страница 34: ...methodforrepairshallbespecifiedbythemanufacturer 21 Multiple repairs will not include the following heater adjustment replacement of magnesium anode replacement of gaskets nor any element wearing duri...

Страница 35: ...f repair Service s seal Service s seal Service s seal Service s seal Owner s name and address Owner s name and address Owner s name and address Owner s name and address Owner s signature Owner s signa...

Страница 36: ...Installation confirmation Type Factory no Date of sale Seller s stamp and signature Warranty coupon 1 Warranty coupon 2 Warranty coupon 3 Warranty coupon 4 Type Type Type Type Factory no Factory no Fa...