![GALLUNOPTIMAL SKALA 400 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/gallunoptimal/skala-400/skala-400_user-manual_3278536027.webp)
GALLUNOPTIMAL
USER MANUAL
8
1.4.2.4 Direct current
range
resolution
accuracy
40mA
10µA
+/-(1,2% rdg + 8dgts)
400mA
100µA
4A
1mA
10A
10mA
Overload protection: mA-range:
fuse 0.5A/600V
A-range:
fuse 10A/600V
Voltage drop:
range 40mA and 4A: 40mV
range 400mA and 10A: 400mV
Max. input current for INPUT:
400mA
Max. input current for 10A:
10A
NOTE:
For measurements >5A: duration <10 seconds, interval >15
minutes
1.4.2.5 Alternating current
range
resolution
accuracy
40mA
10µA
+/-(1,5% rdg + 10dgts)
400mA
100µA
4A
1mA
10A
10mA
+/-(2% rdg + 10dgts)
Overload protection: mA-range:
fuse 0.5A/600V
A-range:
fuse 10A/600V
Voltage drop:
range 40mA and 4A: 40mV
range 400mA and 10A: 400mV
Max. input current for INPUT:
600mA
Max. input current for 10A:
10A
Frequency range:
40 – 400Hz
Response:
True-RMS
NOTE:
For measurements >5A: duration <10 seconds, interval >15
minutes
1.4.2.6 Resistance
range
resolution
accuracy
400Ω
0,1Ω
± (1,2% rdg + 5dgts)
4kΩ
1Ω
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
10kΩ
±(1,5% rdg + 5dgts)
Open Circuit Voltage: ~1V
Overload protection: 250V