ACTIVATION, TROUBLESHOOTING, MAINTENANCE 

Activating the System For the First Time 

 
Connect the feed line if fed from a chlorinated city 
water source, to the storage tank connection. If feed 
line is fed from a fresh water storage tank or a non 
chlorinated water supply, procure a thin ended medi-
cine dropper and drop three to five drops of plain 
unscented laundry bleach into the tubing or an open 
ball valve on top of tank. The ball valve handle is in 
line with the connection port when open. Connect 
tubing to pressurized  water source and turn water 
on. When tank is full, it will feel heavy. Close the 
ball valve and remove system feed tube. 

 

Make sure all water supply & drain lines  

are secure and  free from leakage. Slowly 

turn the system feed valve to on position. 

 
 
Connect tank line to tank. Open faucet by lifting handle to 
allow the air out of the system. Slowly open feed water 
valve to system. 
 
Open the tank valve and drain through the open faucet. 
This will flush the post filter and pressurize the post mem-
brane side of your system.  Once water has stopped run-
ning from the tank, leave faucet handle in the open posi-
tion until all air is out of the system, and water is con-
stantly dripping from the end of the faucet. 
 
Close the faucet and allow 1/2 hour for system to pressur-
ize the tank. Again check for leaks at all connections. Tank 
should be full in approximately 1-1.5 hours. Leave tank 
valve open. 

Do Not Use the First Two Fills of the Tank Reservoir 

Allow the RO Tank two fills  (1.5-2.5 hours each, dependant on pressure) and drain both fills to drain 
through faucet. This will remove factory installed sanitizing solution from the entire system. The sanitiz-
ing solution is of course non toxic, yet should be removed prior to routine use of this appliance. A single 
flush of the system should suffice, nevertheless we suggest a double flush on start up and after pickling 

Maintenance 
 

1) 

Close the ball valve on top of the storage tank(s). NOTE: If your vessel has additional storage tanks 

 

in remote locations such as Fly-Bridge, Wet Bar or Master Suite, make sure all tank valves are 

 closed. 

 

2) 

Open Faucet(s) at galley and any remote locations, to relieve pressure from the system. Standard 

 

faucets will remain open when handle is lifted to up (on) position. 

3) 

Remove the Pre-Filter by turning counter clockwise. Removal of the pre-filter automatically shuts 

 

off the feed water supply. You may close the feed water shut off valve if so desired, for added as-

 surance. 
4) 

Remove the Post Filter by turning counterclockwise. 

5) 

Install new replacement post filter. (Use activated carbon post filter only) Available through our 

 

distributor. Element threads on clockwise. Do not over-tighten as a snug fit with the  “O” rings will 

 

provide a proper seal. 

6) 

Install the new Pre-Filter. Thread into housing clockwise, without over tightening, to achieve an 

 

“O” ring seal. Replacing the Pre-Filter will re-actuate the feed water automatically. If you closed 

 

any feed water valves, re-open them. Close all faucet handles. 

7) 

Open the Ball Valves on all the storage tanks throughout the vessel. Check for leaks. 

8) 

Open faucet once again, and empty the storage tank(s). This will flush the Post Filters and allow 

 

for a fresh tank fill with newly cartridges. 

9) 

Allow 1.5-2.5 hours for tanks to be replenished with a fresh fill of highly pure water. 

 

THIS MAINTENANCE SHOULD BE PERFORMED EVERY 6 MONTHS TO 1 YEAR  

OR AS NECESSARY

 

    7 

Содержание 6001

Страница 1: ...achtmate com GM 5001 Manual Revised 6 20 2002 MODEL 6001 REVERSE OSMOSIS High Purity Water Production System THREE STAGE Filtration for the reduction of Organic Matter Total Dissolved Solids TDS Suspended Solids Chemical Contaminants Bad Taste and Odors MEMBRANE PROCESS for protection against Cysts Bacteria Virus Micro organisms 65 GPD 60 PSI 72F ...

Страница 2: ...ration Routine maintenance is essential to the longevity and overall performance of the Galley Mate RO System Filters should be changed every six to twelve months depending on the quality of the feed water supply FEED WATER SPECIFICATIONS AND OPERATING PARAMETERS CAUTION NO DRINKING WATER SYSTEM SHOULD BE CONSIDERED YOUR PRIMARY SOURCE OF DISINFECTION FOR POTENTIALLY MICROBIOLOGICALLY UNSAFE WATER...

Страница 3: ...is a removable access panel Determine location s of storage tank s A maximum of 15 feet is possible for close installations from tank to faucet s If added faucets are being used you will need to add additional storage tanks at those locations All tubing is individually labeled and color coded for ease of your installation 1 4 Red Connects the feed water line valve to the RO Pre Filter 3 8 Blue Con...

Страница 4: ...PURE WATER FAUCET INSTALLATION 4 Drilling with the Recommended Relton Cutter ...

Страница 5: ...1 PRE 06 2 MEMBRANE 09 3 POST 10 ...

Страница 6: ...ing specialty fau cets as well as the connecting assemblies may differ If you have ordered a specialty faucet from our distribu tor please refer to the installation instructions included with the alternate faucet before you locate and drill any holes for mounting NOTE For certain ice line applications the ice line is provided in 1 4 copper coil tubing Cut reduce length of 1 4 copper to feed with 3...

Страница 7: ... drain saddle valve which fits any 1 1 2 OD straight wall pipe This fitting may be used in under galley sink installations where the riser above the P Trap is 1 1 2 in diameter This fitting can be in stalled either in a vertical position or on a horizontal position as long as the fitting is above the trap When installing the Galley Mate assembly in an engine room you may utilize the saddle fitting...

Страница 8: ...ctory installed sanitizing solution from the entire system The sanitiz ing solution is of course non toxic yet should be removed prior to routine use of this appliance A single flush of the system should suffice nevertheless we suggest a double flush on start up and after pickling Maintenance 1 Close the ball valve on top of the storage tank s NOTE If your vessel has additional storage tanks in re...

Страница 9: ...FOR A REMOTE TANK INSTALLATION PLACE A QUICK CONNECT T ON THE LINE TO PRIMARY TANK AND INTERCONNECT TANK LINES NOTICE OPTION B FOR INSTALLATIONS TO UPPER DECKS OR BRIDGE TO FEED ICE MAKERS CONNEC TION SHOULD BE MADE FROM TANK LINE UTILIZING A 10 INLINE FILTER AT THE POINT OF USE TO KEEP TASTE OUT OF LINE THIS IS TO BE RUN IN 3 8 MINIMUM NOTE LARGER TANKS ARE AVAILABLE OPTION B GALLEY MATE IS A PRO...

Страница 10: ...ring pets Enjoy this appliance and put it to work for you START UP TIPS YOUR REVERSE OSMOSIS SYSTEM WILL PRODUCE UP TO 65 GALLONS DAY DEPENDING ON THE TEMPERATURE THE PRESSURE AND THE LEVEL OF DISSOLVED SOLIDS TO BE REMOVED FROM THE WATERS THAT FEED THE SYSTEM For example on start up we advise that you wait up an average of 4 hours for a tank to fill discard the water and repeat the process This i...

Отзывы: