STRUCTURe

Painted galvanised sheet steel structure (RAl9002) for an attractive look and 
effective resistance to corrosive agents�
Fastening devices are made of non-oxidizable materials, or carbon steel that 
has undergone surface-passivating treatments�
The compressor compartment is completely sealed and may be accessed on 
3 sides thanks to easy-to-remove panels that greatly simplify maintenance 
and/or inspection�
Sound insulation, available on request, can further reduce the noise emissions 
of the unit�

CUSTOMISeD hyDRaUlIC KIT 

-   High head pump made entirely of stainless steel, already configured for use 

with mixtures of water and ethylene glycol up to 35% and provided with 
internal thermal protection� It is housed in the compressor compartment 
and is easy to reach thanks to the removable perimeter panels�

-  Expansion tank 
-  Safety valve� 
-  Filling cock (included)�
-  Automatic vent valve�
-  Water differential pressure switch and outlet water temperature probe with 

anti-freeze thermostat function�

-  Mechanical Y filter supplied as a standard feature on all models to protect 

the evaporator (included)�

COOlInG CIRCUIT

-  BlDC-type compressor housed in a compartment that can be sound 

insulated�

-   Brazed plate heat exchangers made of STAInlESS steel and optimised for 

use with R410A�

-  Finned block condenser with 8 mm copper piping and aluminium fins, 

characterised by ample heat exchange surfaces�

-  Dehydrating filter�
-  Flow indicator with humidity indicator�
- Thermostatic valve with external equalization and integrated MoP function�
-  Cycle-reversing valve (MPI DC H)�
-  Single-acting valves (MPI DC H)�
-  liquid receiver (MPI DC H)�
-  High and low pressure switches�
-  Safety valve�
-  Schrader valves for checks and/or maintenance�
-  Refrigerant pressure gauges (optional)�

Fan DRIVe aSSeMBly

Electric fan with 6-pole external rotor motor directly keyed to the axial fan, 
with internal thermal protection on the windings, complete with safety grille 
and dedicated supporting structure�
The fan is housed in a special compartment having a profile designed to 
optimise ventilation� 
The use of finned block heat exchangers with 8mm diameter pipes reduces 
pressure drops on the air side, thus significantly improving the noise levels 
of the units�
The condensation control system continuously and automatically regulates 
the fan speed, further limiting the noise emissions of the unit during nighttime 
operation and under partial load conditions�

FInneD BlOCK heaT eXChanGeR 

Made of 8mm diameter copper pipes and aluminium fins, generously sized�
The special engineering of the heat exchangers allows defrost cycles to be 
carried out at maximum speed in the models with heat pump operation, which 
brings clear benefits in terms of the integrated efficiency of the whole cycle�

eleCTROnIC MICROPROCeSSOR COnTROl

The electronic control enables the complete control of the MPI DC unit� It can 
be easily accessed through a polycarbonate flap with IP65 protection rating�

The modulation of capacity enables the unit to operate even in systems where 
the water content is low, without the use of an inertial water buffer tank� By 
reading the outdoor air temperature, it can automatically change the setpoint 
to adapt it to the outdoor load conditions or keep the unit running even in the 
harshest winter conditions� 
The basic controller comes complete with the MoDBuS protocol and enables 
an immediate connection to ERGo networks�

Main functions:
-  Continuous modulation of compressor capacity�
-  Control of outlet temperature
-  Control over the temperature of water entering the evaporator�
-  Defrosting management (MPI DC-H)
-  Control of fan speed (optional)
-  Complete alarm management�
-  Dynamic control of the setpoint according to the outdoor air temperature�
-  Can be connected to an RS485 serial line for supervisory / teleassistance 

operation

-  option of connecting a remote terminal that duplicates the control functions

Devices controlled:
- Compressor
-  Fans
-  Cycle-reversing valve (MPI DC-H)�
-  Water circulation pump
-  Antifreeze heating elements (optional)
-  Alarm signalling relay

on request, it is possible to install the advanced controller whose functions 
extend to: 
-  lAn networks 
-  Smart Defrost System

eleCTRIC COnTROl BOaRD

Electric control board constructed and wired in accordance with the Directive 
on electromagnetic compatibility and related standards� Made of steel sheet, 
it is also protected by the enclosing panels of the unit�

OPTIOnS

Incorporable hydronic kits
Condensation control
low noise execution
Refrigerant pressure gauges
Antifreeze heating elements on the water circuit
Electronic thermostatic valve
Heat recovery 25% (chiller)
Special exchangers (hydrophilic treatment, copper-copper, cataphoresis, 
anti-corrosion)

aCCeSSORIeS aVaIlaBle

Remote control boards
Base vibration dampers
Metal grilles to protect exchangers
MYCHIllER DHW

COnSTRUCTIVe FeaTUReS

Содержание MPI DC 08

Страница 1: ...MPI DC 08 kW 29 kW R410A eco Technical MANUAL FOR CHILLERS AND HEAT PUMPS GB CHILLERS AND HEAT PUMPS DC INVERTER...

Страница 2: ...sors brazed plate heat exchangers liquid receivers pipes control and safety valves which are individually provided where required with certification in accordance with current directives the category...

Страница 3: ...data are reported on the rating label in this page The label shows the following data Series and size of the unit Date of manufacture Main technical data Manufacturer The label is applied on the unit...

Страница 4: ...equipped with an automatically controlled oil heating system to avoid oil dilution by the refrigerant when the compressor is stopped The compressor motor is a permanent magnets brushless alternating...

Страница 5: ...automatically regulates the fan speed further limiting the noise emissions of the unit during nighttime operation and under partial load conditions FINNED BLOCK HEAT EXCHANGER Made of 8mm diameter cop...

Страница 6: ...pressure switch fan compartment 5 Automatic air vent valve 6 Expansion tank fan compartment 7 Buffer tank accessory 8 4 way valve MPI DC H 9 Electronic expansion valves 10 Water safety valve 11 Liqui...

Страница 7: ...switch fan compartment 5 Automatic air vent valve 6 Expansion tank fan compartment 7 Buffer tank accessory 8 4 way valve MPI DC H 9 Electronic expansion valves 10 Water safety valve 11 Liquid receiver...

Страница 8: ...ure switch fan compartment 5 Automatic air vent valve 6 Expansion tank fan compartment 7 Buffer tank accessory 8 4 way valve MPI DC H 9 Electronic expansion valves 10 Water safety valve 11 Liquid rece...

Страница 9: ...or 0 Model size 1 4 Operation H Water chiller C Heat pump H Supply voltage 0 Standard 400 3N 50 0 Single phase M Refrigerant A R410A high efficiency A Revision A Initial A Expansion valve A Electronic...

Страница 10: ...pply V ph Hz 230 1 50 400 3N 50 400 3N 50 400 3N 50 400 3N 50 Rated cooling capacity kW 10 6 14 3 18 2 22 9 29 1 Total power input kW 3 35 4 78 7 63 7 77 12 3 EER rated capacity 3 16 2 99 2 39 2 95 2...

Страница 11: ...Total power input with pump kW 2 8 3 6 5 3 8 2 8 3 12 9 Rated heating capacity kW 8 89 11 5 15 7 21 6 24 6 33 7 Total power input in heating mode kW 2 81 3 56 4 96 7 48 7 86 11 7 COP rated power 3 16...

Страница 12: ...07 2 53 1 14 2 37 1 22 14 9 3 27 0 87 3 11 0 94 2 95 1 00 2 78 1 07 2 62 1 15 2 46 1 23 15 10 3 38 0 87 3 21 0 93 3 05 1 00 2 89 1 07 2 71 1 15 2 55 1 23 16 11 3 49 0 86 3 32 0 93 3 15 1 00 2 98 1 07...

Страница 13: ...95 14 9 4 62 1 43 4 41 1 53 4 20 1 62 3 98 1 72 3 75 1 83 3 49 1 95 15 10 4 79 1 43 4 56 1 52 4 35 1 62 4 12 1 72 3 88 1 83 3 61 1 95 16 11 4 95 1 42 4 72 1 52 4 50 1 61 4 26 1 71 4 01 1 83 3 74 1 95...

Страница 14: ...57 5 74 2 73 5 42 2 91 14 9 7 13 2 16 6 84 2 30 6 56 2 43 6 26 2 57 5 94 2 74 5 61 2 92 15 10 7 37 2 15 7 07 2 29 6 78 2 42 6 47 2 57 6 15 2 74 5 81 2 92 16 11 7 62 2 15 7 31 2 29 7 01 2 42 6 69 2 57...

Страница 15: ...2 1 22 14 9 3 21 0 87 3 05 0 94 2 89 1 00 2 73 1 07 2 57 1 15 2 41 1 23 15 10 3 31 0 87 3 15 0 93 2 99 1 00 2 83 1 07 2 66 1 15 2 50 1 23 16 11 3 42 0 86 3 25 0 93 3 09 1 00 2 92 1 07 2 75 1 15 2 58 1...

Страница 16: ...5 1 83 3 31 1 95 14 9 4 53 1 43 4 33 1 53 4 12 1 62 3 91 1 72 3 67 1 83 3 42 1 95 15 10 4 69 1 43 4 47 1 52 4 27 1 62 4 04 1 72 3 80 1 83 3 54 1 95 16 11 4 85 1 42 4 63 1 52 4 41 1 61 4 18 1 71 3 93 1...

Страница 17: ...2 2 91 14 9 7 00 2 16 6 72 2 30 6 44 2 43 6 14 2 57 5 83 2 74 5 51 2 92 15 10 7 23 2 15 6 94 2 29 6 65 2 42 6 35 2 57 6 03 2 74 5 70 2 92 16 11 7 48 2 15 7 17 2 29 6 87 2 42 6 56 2 57 6 24 2 74 5 90 2...

Страница 18: ...14 20 3 75 15 70 3 74 40 45 8 11 3 78 9 37 3 90 11 40 4 03 13 80 4 11 15 30 4 12 45 50 7 94 4 03 9 19 4 19 11 20 4 37 13 50 4 48 14 90 4 51 MPI DC 010 H Rated data at intermediate frequency 25 30 5 1...

Страница 19: ...45 18 60 8 17 21 10 8 31 25 10 8 44 30 20 8 55 33 20 8 58 45 50 18 40 8 91 20 80 9 05 24 70 9 21 29 70 9 33 32 60 9 39 MPI DC 023 H Rated data at intermediate frequency 25 30 12 80 4 47 14 50 4 42 17...

Страница 20: ...within the range defined by the operating limits Attempting to operate the units beyond these limits could cause irreparable damage to the units themselves 8 1 Operating limits in chiller mode Outlet...

Страница 21: ...nd water outlet temperature CPF PT Corrective coefficient of cooling heating capacity CPA Correction coefficient of electrical input CQw Correction coefficient of water flow rate C pw1 Correction coef...

Страница 22: ...PORTATA l h PERDITE kPa MPIDC018 MPIDC023 MPIDC029 MPI DC 08 014 MPI DC 018 029 All copying even partial of this manual is strictly forbidden RG66007970 Rev 01 10 PRESSURE DROPS 10 1 PRESSURE DROPS WA...

Страница 23: ...000 10000 12000 p kPa Qw l h MPI DC 010 029 MPI DC 08 All copying even partial of this manual is strictly forbidden RG66007970 Rev 01 10 PRESSURE DROPS 10 2 PRESSURE DROPS OF Y FILTER The diagram show...

Страница 24: ...0 6000 6400 PORTATA l h PREVALENZA kPa MPIDC018 MPIDC023 MPIDC029 MPI DC 018 029 All copying even partial of this manual is strictly forbidden RG66007970 Rev 01 11 AVAILABLE HEAD OF THE UNIT The diagr...

Страница 25: ...when the unit is disconnected from the power supply It is of fundamental importance that the incoming water supply is hooked up to the connection marked Water Inlet Otherwise the evaporator would be...

Страница 26: ...TER CIRCUIT PLUMBING DIAGRAMS MPI DC evaporator and pump MPI DC evaporator pump and tank LEGEND VS Safety valve EV Evaporator PD Differential pressure switch MA Water pressure gauge VAS Air vent valve...

Страница 27: ...refer to the wiring diagram supplied with the units MPI DC 08 M 010 M 014 018 023 029 Maximum power input kW 4 1 5 6 7 1 10 7 10 8 21 9 Maximum current absorption A 16 26 6 20 22 28 5 43 Starting abso...

Страница 28: ...and PCDS remote control panel Note Should the unit go into an alarm status a voltage of 24V will be present on the terminals of the electric control panel where an interface with a voltage free contac...

Страница 29: ...DIMENSIONS MPI DC 08 Legend 1 Water inlet 1 female 2 Water outlet 1 female 3 Safety valve discharge outlet provided with rubber ring holder 4 Water supply male optional tap 5 Water drainage female 6 P...

Страница 30: ...L DIMENSIONS MPI DC 10 18 Legend 1 Water inlet 1 female 2 Water outlet 1 female 3 Safety valve discharge outlet provided with rubber ring holder 4 Water supply male optional tap 5 Water drainage femal...

Страница 31: ...IMENSIONS MPI DC 23 29 Legend 1 Water inlet 1 female 2 Water outlet 1 female 3 Safety valve discharge outlet provided with rubber ring holder 4 Water supply male optional tap 5 Water drainage female 6...

Страница 32: ...lease contact the manufacturer to check for feasibility In the design of the MPI DC series special care has been taken to minimise noise and vibrations transmitted to the ground Even greater insulatio...

Страница 33: ...anual is strictly forbidden RG66007970 Rev 01 15 Installation clearance requirements MPI DC 10 18 MPI DC 23 29 COIL PLUMBING CONNECTION SIDE ELECTRIC CONTROL BOARD COIL SIDE COIL PLUMBING CONNECTION S...

Страница 34: ...fan air flow A prevalent wind blowing from a direction opposite to the fan air flow will reduce the maximum air temperature to a lower value than specified in the operating limits A wind blowing in t...

Страница 35: ...35 All copying even partial of this manual is strictly forbidden RG66007970 Rev 01 NOTES...

Страница 36: ...Wolf Schweiz AG Dorfstrasse 147 CH 8802 Kilchberg Telefon 41 43 500 48 00 Fax 41 43 500 48 19 info wolf klimatechnik ch www wolf klimatechnik ch...

Отзывы: