UNDERSTANDING YOUR ENERGIZER CONTROLLER
Current Display
Shows the amount of load on the
energizer / fence zones
Voltage Display
Shows energizer / earth / fence zones voltage
Status LED
Provides quick
indication of the
fence status
Zone
Indicators
Displays which
energizer / earth
/ fence zones are
operating and if
they are in alarm
Settings buttons
Change alarm levels and
energizer output voltage
Standby button
Turns the energizer pulses
on and off
Navigation Buttons
View energizer / earth /
fence zones to see zone
performance
Quickscan
Bargraph
Gives fast visual
indication of fence
voltage
Zone Indication
Arrow
Highlights which
energizer / earth /
fence zone is being
shown on the main
display
Status LED
Green
The energizer and fence are operating normally
Red
The energizer has detected a fault. Check the LCD screen to
determine where the problem is.
Flashing Red
The energizer output voltage is low.
Quickscan Bargraph
The Quickscan bargraph gives quick visual indication of the energizer output voltage.
Each bar illuminated represents approximately 1KV output.
Green Segments
Your fence is performing well. No attention is required.
Yellow Segments
Your fence is under some load but is still delivering an
effective shock.
Red Segments
Your fence is under heavy load and requires maintenance.