Gallagher 3E3618 i Series Energizer User Manual

35 

English

To fence

To fence

To earth/ground

Status LED

Step 3:

Connect to the fence, energizer and earth stake. 

The stock protec  on wire can be a  ached to either side of the Fence Monitor (the 
side most accessible to stock), by placing it under the bolt on one of the Output 
terminals ( ). 

To next fence 
zone

To Earth/Ground

Note: 

To get an accurate current reading, the power to a zone must pass through the 

Fence Monitor.

Содержание 3E2748

Страница 1: ...FENCE ENERGIZER iSERIES Instructions ENG...

Страница 2: ...hilst every e ort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or ac o...

Страница 3: ...mote with mul ple Energizers 27 Understanding your Electric Fence 29 3E2748 Fence Monitor User Manual Introduc on 33 Installa on 34 Using your Fence Monitor 37 Choosing an Installa on Loca on 39 Troub...

Страница 4: ......

Страница 5: ...zer For any two separate electric animal fences each supplied from a separate energizer independently med the distance between the wires of the two electric animal fences shall be at least 2 5m If thi...

Страница 6: ...n the sign shall be black and shall be either the substance of CAUTION Electric Fence or the symbol shown The inscrip on shall be indelible inscribed on both sides of the warning sign and have a heigh...

Страница 7: ...the fence It may take several days to train the animal and the fence may require minor adjustments Animals that are prone to jumping may be di cult to confine You may need to try di erent fence heigh...

Страница 8: ...d into the wall through the moun ng holes in each corner Place the black bezel on the controller d Route the controller cable to the energizer and plug it into the data connector on the back cover Ste...

Страница 9: ...t to the green terminal on the energizer 2 A ach the cable to the earth system by removing 10cm 4 of insula on from the cable at each Earth Stake G879 and then clamp the exposed wire to each stake usi...

Страница 10: ...of the cable to the fence using a Joint Clamp G603 For instruc ons on fence installa on see the Gallagher Power Fence Manual or go to www gallagher co Step 4 Turn the Energizer On a Plug the energize...

Страница 11: ...when the energizer has detected a fence fault Solid red when there is a sudden increase in fence load Wire to Energizer Controller The connector for the energizer controller is on the back cover This...

Страница 12: ...rmance Quickscan Bargraph Gives fast visual indica on of fence voltage Zone Indica on Arrow Highlights which energizer earth fence zone is being shown on the main display Status LED Green The energize...

Страница 13: ...f up to 6 Fence Monitors or Alarm Systems See Accessories p 18 Naviga on Bu ons The naviga on bu ons allow you to view the performance of di erent areas of your fence system By pressing or you can scr...

Страница 14: ...nd the energizer output voltage is 7 3KV in this case The quickscan bargraph display is also indica ng an output voltage of over 7KV Controller showing the energizer opera ng normally Voltage Alarm If...

Страница 15: ...s If the current goes above the alarm level you have set then the Energizer icon will flash and the status LED will flash red Controller showing the energizer in current alarm Status LED flashes red A...

Страница 16: ...d wait 30 seconds Check the earth system voltage using the naviga on keys The earth voltage should be 0 2 0 3KV or less If it is higher add earth stakes un l 0 2 0 3KV is achieved In dry condi ons or...

Страница 17: ...s ng Turning O Alarms sec on p 15 Low Ba ery When viewing a zone if the ba ery icon is displayed then the zone device needs a ba ery replacement Controller showing the output voltage being adjusted Ad...

Страница 18: ...peace of mind Important Only 1 SMS Energizer Controller can be used per energizer Using your mobile phone you can Receive automa c alerts when the energizer detects a fence fault Turn your energizer o...

Страница 19: ...checked by a professional electrician Displaying Error 14 19 Internal energizer fault Turn energizer o for 30 seconds then turn back on If the error remains return the energizer to your Gallagher deal...

Страница 20: ......

Страница 21: ...ENERGIZER REMOTE FAULT FINDER...

Страница 22: ...anual Remote Readings 23 Installing the ba ery 24 Features 24 Checking your fence and finding faults 25 Detec ng Alarms 26 Turning the Energizer On O Standby 26 Using your Remote with mul ple Energize...

Страница 23: ...stal Display Standby Indicates the energizer is in Standby mode Energizer status Current Display Direction of current flow Voltage Display Fence Zone indicators Displays which fence zones are operatin...

Страница 24: ...e of approximately 6 months A flat ba ery may give false measurements so replace the ba ery when the icon shows FEATURES The Gallagher Energizer Remote and Fault Finder enables you to do the following...

Страница 25: ...e is a fault on the fence 1 Following the direc on of the current take readings approximately every 50 100m or at junc on points along your fence line Note At a junc on point follow the wire with the...

Страница 26: ...alarms Energizer status Not in alarm Connected fence zones None are in alarm Energizer in alarm Connected fence zones 1 and 4 are in alarm System status is AL Alarm alarms present TURNING THE ENERGIZ...

Страница 27: ...annel you wish to communicate with is displayed Deleting a channel 1 Hold down any two bu ons for 3 seconds The Remote display scrolls through all the filled channels 2 Release the bu ons when the ene...

Страница 28: ...Gallagher 3E3618 i Series Energizer User Manual 28 English Channel Energizer 1 2 3 4 5 6 7 8 9 Use this table to record which channel number is set to each energizer...

Страница 29: ...a minor flow of water current will flow into these leaks and reduce overall pressure voltage at point B the pressure is s ll significant enough to deliver enough water current at point B as needed Whe...

Страница 30: ......

Страница 31: ...FENCE MONITOR...

Страница 32: ...Contents 3E2748 Fence Monitor User Manual Introduc on 33 Installa on 34 Using your Fence Monitor 37 Choosing an Installa on Loca on 39 Troubleshoo ng 42...

Страница 33: ...When a zone falls below a set voltage level an alarm is sent to the Energizer Controller indica ng that zone is below the set alarm voltage Kit Contents The following contents are included with your...

Страница 34: ...agram B Step 2 Mount the unit to a post in either of the following ways Screw to a wooden post diagram A Screw holes for moun ng to a wooden post Diagram A INSTALLATION For how to set up fence zones o...

Страница 35: ...ce energizer and earth stake The stock protec on wire can be a ached to either side of the Fence Monitor the side most accessible to stock by placing it under the bolt on one of the Output terminals T...

Страница 36: ...over The electrified stock protec on wire is used to stop animals from damaging the Fence Monitor Stock protec on wire Step 4 1 Set the fence zone 1 6 Important Each Fence Monitor requires a unique zo...

Страница 37: ...e way as the Energizer output voltage and alarm informa on Changing Zones To change an exis ng fence zone number to another zone 1 Put the Energizer into Standby mode 2 Remove the cover 3 Set orange d...

Страница 38: ...gizer User Manual 38 English Important Battery Information Only use Alkaline AA ba eries Remove ba eries when not in use Es mated ba ery life 1 2 years Low ba ery indica on is shown on controller as b...

Страница 39: ...zones To help iden fy where faults are the Fence Monitors must be installed in sec ons of the fence that supply current to di erent parts of the farm The Fence Monitor can only iden fy faults in fenc...

Страница 40: ...Gallagher 3E3618 i Series Energizer User Manual 40 English 1 3 4 2 Zone 1 Zone 2 Zone 3 Zone 4 Independent Leadouts Independent Zones...

Страница 41: ...f the fault is located in the smaller area and the larger area then fault is most likely in the smaller area If only in the larger area then the fault is in the larger areas but not in the smaller sub...

Страница 42: ...fence voltage is less than 500V The energizer is incorrectly connected to the fence Replace ba eries Install ba eries ba ery holder correctly Remove ba ery holder for 5 minutes to reset the Fence Mon...

Страница 43: ...SMS ENERGIZER CONTROLLER...

Страница 44: ...ergizer Controller User Manual Understanding your SMS Energizer Controller 45 Understanding SMS messages 47 Troubleshoo ng 51 Standard Mode Alarm System fault finding 52 Waste electrical and electroni...

Страница 45: ...zer Controller Only a Standard size SIM is compa ble Important Only 1 SMS Energizer Controller can be used per Energizer Please use the GSM card of a provider which guarantees you a su cient cell rece...

Страница 46: ...ur mobile phone to the SMS Energizer Controller Text REG to the SIM card phone number inside the SMS Energizer Controller The SMS Energizer Controller will send a response confirming that your phone h...

Страница 47: ...S OK MAINS FAILURE LOW BATTERY SIG 0 100 Informa on Descrip on OK Indicates that the SMS Energizer Controller is on and working MAINS FAILURE Indicates that the mains supply has failed LOW BATTERY Ind...

Страница 48: ...2kV Z2 18A 1 9kV In Example 2 the Energizer earth zone 1 and zone 2 are in voltage alarm Example 3 SMS MAINS FAILURE LOW BATTERY SIG 57 EN MAINS POWER FAILURE In Example 3 the Energizer and Energizer...

Страница 49: ...nce Zones are OK Turn Energizer mains power alarm on o Indicates whether an alarm message will be sent or not in the event of the Energizer power supply failing A ENERGIZER ON POWER ALARM ON RESTORE O...

Страница 50: ...le number 2 DEREG ALL Communication Status Indicators SMS Energizer Controller LED Explana on Blue LED On A emp ng to connect to network Flashing fast Communica ng to the network Red LED Flashing slow...

Страница 51: ...obile number 3 when trying to send REG to register a third phone to the SMS Energizer Controller Two phones are already registered to your SMS Energizer Controller You will need to de register one of...

Страница 52: ...a manner that protects human health and the environment For more informa on about where you can drop o your waste equipment for recycling please contact your local city recycling o ce or the dealer fr...

Страница 53: ...ALARM SYSTEM...

Страница 54: ...3E3115 Alarm System User Manual Important Informa on 55 i Series Alarm System 56 Quick Installa on Guide 57 Advanced Features 58 LED Status Indicators 64 Fault Finding 64 Specifica ons 64 External Ba...

Страница 55: ...ithin 10m 33 of any power telecommunica ons or other system Use high voltage lead out cable in buildings to e ec vely insulate from the earthed structural parts of the building and where soil could co...

Страница 56: ...alarms and or Strobe lights The system no fies you if the voltage on the fence drops to an insu cient level due to fence faults or wire breakages The Gallagher Alarm system can be configured as below...

Страница 57: ...e ngs p 59 2 Mount to the wall and connect the high voltage fence return and earth ground terminals 3 Connect to AC adaptor power supply 4 Op onal connec ons Via RJ12 cable to i Series system or to an...

Страница 58: ...e Alarm System remove from the wall and unscrew the 6 screws on the back of the unit To make changes to the alarm system se ngs the alarm unit must have all power removed 1 2 7 1 i Series Zone address...

Страница 59: ...n standard mode 0 Fence alarm OFF 8 1kV fence alarm threshold 9 2kV fence alarm threshold A 3kV fence alarm threshold B 4kV fence alarm threshold C 5kV fence alarm threshold D 6kV fence alarm threshol...

Страница 60: ...selected the ALARM TIME determines how long the relay is turned on for Refer to Alarm Time Delay Time p 62 for further details When latched is selected the relays stay on un l the reset bu on is press...

Страница 61: ...resistors 3 External Inputs 15V This connector is rated 2A maximum Up to three inputs such as mo on sensors or reed switches can be connected These can be configured as balanced security or switch inp...

Страница 62: ...from happening press the on o push bu on before the delay me elapses 7 Relays The relays have a powered 12 15V DC common COM by factory default That is connectors J5 J9 J13 have links between pin 1 a...

Страница 63: ...C GND Relay 1 N O COM N C GND Relay 2 N O COM N C GND Relay 3 Relay 1 powered N O relay 1 GND Strobe N O relay 2 GND Siren GND Ba ery Relay 2 powered Relay 3 powered 63 Gallagher 3E3618 i Series Ener...

Страница 64: ...r supply SMS message EN OA x ykV Alarm system in voltage alarm SMS message EN OA x ykV One of the external inputs ac vated SMS message EN ERROR Energizer pulse is missed by the alarm system SPECIFICAT...

Отзывы: