Fault
Possible Causes(s)
Solu
Ɵ
on
Energizer doesn’t operate
Energizer O
ff
Switch
ON
Incorrect ba ery voltage
For B700: use 12V ba ery, for
B1600: use 12V, 24V or 36V ba ery
Incorrect ba ery connec on
Connect red lead to the (+)
terminal of ba ery, black lead to (-)
terminal
Ba ery is
fl
at
Ba ery voltage should be greater
than 11.8V
Faulty Energizer
Have Energizer repaired
Electric fence voltage is
below 3000V or your stock
are escaping
Faulty Energizer
Turn Energizer OFF and remove the
fence wire from the Red terminal
(For B1600 remove the fence wire
from the Yellow terminal if the
REDUCED POWER op on is being
used).
Turn Energizer ON again.
Using a Digital Volt Meter (G5030)
check the voltage across the
terminals. If the voltage is less than
5000V, have Energizer repaired.
Inadequate earthing
Improve the earth system by adding
more galvanised earth stakes to the
earth system un l the earth voltage
is 200V or below.
Short on the fence line
Check the electrical connec ons
are secure
eg. from the fence to the red
terminal, from the earth system to
the green terminal, at gates etc.
Check the voltage on the fence
every 33m (100 ) using the Digital
Volt Meter. Note if the voltage is
dropping. The closer to a fault, the
lower the voltage reading will be.
Become aware of things that cause
faults and always be on the lookout
for: stray pieces
of
wire on the
fence, heavy vegeta on growth,
cracked or broken insulators,
broken wires.
TROUBLESHOOTING