19.11.2021, 11:52
Base Block
base.galileosky.com/articles/#!en-documentation/base-block-user-manual
9/28
LED indicators
Red
LED is on when the power unit is connected to the tracking device.
Yellow
LED is on when the microcontroller is running (blinks with the frequency of 1 Hz). It
is also used to indicate the bootloader mode.
Green
LED shows the GLONASS/GPS unit status.
Blinking frequency,
times
Description
3
GLONASS/GPS unit is not found or is at the
initialization stage
2
GLONASS/GPS unit is found but correct
coordinates are absent
1
GLONASS/GPS unit works properly, coordinates
are found and updated once a second
Blue
LED shows the GSM/3G-unit status.
Blinking frequency,
times
Description
3
GSM/3G-unit is not found or is at the
initialization stage
2
GSM/3G-unit is found, GPRS-session is
activated
1
GSM/3G-unit works properly, server is
connected
Connecting to PC
In order to connect the tracking device to PC, use USB A – Micro-USB B.
Using defective cables (with disconnected grounds contacts on connectors) may lead to
device’s failure.