DMC-100/1500 Command Reference
UL
•
143
DMC-1000
DMC-1500
UL
FUNCTION:
Upload
DESCRIPTION:
The UL command transfers data from the controller to a host computer through port 1.
Programs are sent without line numbers. The Uploaded program will be followed by a
<control>Z or a \ as an end of text marker.
ARGUMENTS:
None
USAGE: DEFAULTS:
While Moving
Yes
Default Value
0
In a Program
No
Default Format
-
Command Line
Yes
Can be Interrogated
No
Used as an Operand
Yes
OPERAND USAGE:
When used as an operand, _UL gives the number of available variables.
CONTROLLER
NUMBER OF AVAILABLE VARIABLES
DMC-1500 254
DMC-1010 thru DMC-1040
126
DMC-1050 thru DMC-1080
254
DMC-1010-MX thru DMC-1040-MX
510
RELATED COMMAND:
DL Download
EXAMPLES:
UL; Begin
upload
#A Line
0
NO This is an Example
Line 1
NO Program
Line 2
EN Line
3
<cntrl>Z Terminator