68
●
Chapter 6 Programming Motion
DMC-18x2
Electronic gearing where slave axes are scaled to
master axis which can move in both directions.
Electronic Gearing
GA
GR
GM (if gantry)
Master/slave where slave axes must follow a
master such as conveyer speed.
Electronic Gearing
GA
GR
Moving along arbitrary profiles or mathematically
prescribed profiles such as sine or cosine
trajectories.
Contour Mode
CM
CD
DT
WC
Teaching or Record and Play Back
Contour Mode with Automatic Array
Capture
CM
CD
DT
WC
RA
RD
RC
Backlash Correction
Dual Loop
DV
Following a trajectory based on a master encoder
position
Electronic Cam
EA
EM
EP
ET
EB
EG
EQ
Smooth motion while operating in independent axis
positioning
Independent Motion Smoothing
IT
Smooth motion while operating in vector or linear
interpolation positioning
Vector Smoothing
VT
Smooth motion while operating with stepper
motors
Stepper Motor Smoothing
KS
Gantry - two axes are coupled by gantry
Gantry Mode
GR
GM
Independent Axis Positioning
In this mode, motion between the specified axes is independent, and each axis follows its own profile.
The user specifies the desired absolute position (PA) or relative position (PR), slew speed (SP),
acceleration ramp (AC), and deceleration ramp (DC), for each axis. On begin (BG), the DMC-18x2
profiler generates the corresponding trapezoidal or triangular velocity profile and position trajectory.
The controller determines a new command position along the trajectory every sample period until the
specified profile is complete. Motion is complete when the last position command is sent by the
DMC-18x2 profiler. Note: The actual motor motion may not be complete when the profile has been
completed, however, the next motion command may be specified.
The Begin (BG) command can be issued for all axes either simultaneously or independently. XYZ or
W axis specifiers are required to select the axes for motion. When no axes are specified, this causes
motion to begin on all axes.
The speed (SP) and the acceleration (AC) can be changed at any time during motion, however, the
deceleration (DC) and position (PR or PA) cannot be changed until motion is complete. Remember,
motion is complete (AM) when the profiler is finished, not when the actual motor is in position. The
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание DMC-18 2 Series
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...