Fertijet
- Installation Guide and User Manual
EC/PH Electrodes
Clean the EC/pH electrodes on a weekly basis� Thus it is recommended to
remove any impurity on the electrodes for 10 minutes with the acid solution
prepared in the acid tank�
Use 4.0 and 7.0 Buffer solutions for the pH, and the 1.4 mS/cm solution for
the EC�
For the pH electrode, measure how long it takes the electrode to
reach a
reading of 4�0 to 7�0� For this exercise use the pH 4�0 and 7�0 solutions; Whereas
if the time elapsed exceeds 30 seconds, the pH electrode should be replaced to
assure control�