TROUBLESHOOTING
Symptom
Possible reason
Sulution
The booster pump
doesn’t start when
commanded�
a� Check the main
power�
b� Check the ~24v
breaker in the Fertijet.
c� Check the ~24V fuse
in the Galileo�
d� Make sure line
pressure is above the
stated value of the
pump�
The booster pump
rotates but no suction
power�
a� Check the motor
direction� It must be
as indicated by the
arrow on the motor or
on the pump body�
b� Open the union (or
flange) at the pump
inlet and verify the
free flow of water into
the pump�
a� Change the
sequence between
2 phases (By
electrician)
Difference between the
line pressure and the
suction pressure is less
than 25 m
Check if the venturi
blocks orifice has been
deformed and replace
them if necessary
�