![Galaxy TOXIC TRAMPOLINE MELTDOWN Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/galaxy/toxic-trampoline-meltdown/toxic-trampoline-meltdown_assembly-manual_3264373016.webp)
16
Whilst others imitate we continue to innovate. Why settle for a copy when you can have the original?
Tel: 941 697 0324 | Fax: 941 697 1249
[email protected] | www.galaxymultirides.com
Trouble Shooting
Your Meltdown has been meticulously engineered and thoroughly tested before delivery. If, however, you
unexpectedly experience difficulties, please check out the guide below.
We DO NOT warranty any parts
that are damaged from using a generator
.
If you have any questions or need help please contact us on:
941 697 0324 or [email protected].
REGION
POWER REQUIREMENTS
Europe/Asia/South America/ Australasia
230 volts mains power single phase 4 amps at 50htz.
North America
110 volts mains power single phase 5.5 amps at 60htz.
Japan
90 -110 volts mains power single phase 5.5 amps at 60htz.
POWER REQUIREMENTS
ELECTRICITY
WHAT IS THE POWER SOURCE
We recommend to work on mains power.
THE USE OF PORTABLE
GENERATORS TO POWER THE MACHINE CAN DAMAGE THE
ELECTRONICS
. But, i
f you must use a portable generator, invest in
a branded generator such as Honda, Kawasaki or Briggs & Stratton.
You will need a 3KVA diesel powered generator, as these give the
best power and performance. Use an in line power surge protector
between the generator and the control console.
HOW MANY AMPS ARE NEEDED
A Meltdown requires 5.5 amps.
WHAT IS THE OUTPUT POWER FROM
THE POWER SOURCE
A Meltdown requires 110-120 volts.
VOLTAGE/AMP METER
All machines manufactued after 1/8/2014 have a voltage/amp meter
installed in the control console. This allows you to see the exact
voltage/amps you’re receiving from the power source.
LENGTH OF THE EXTENSION CORD
AND GAUGE OF THE POWER CORD
Longer thinner power cords will always lose voltage.
THE RIDE IS REALLY SLOW
Check that you have enough voltage & amps to the machine. Once
you go over a 30’ extension cord, this can contribute to voltage
drop: the longer the cord, the worse the problem will be.
THE RIDE MOVES FREELY WHEN IT’S
NOT POWERED WHEN I MOVE IT
This is called back driving. It is a characteristic of this type of gearbox.
Please be assured it has
NO DETRIMENT
to the machine at all. It
will not happen when the machine is in operation.