background image

8

 

 

Counter Setting 

5. Counter 

Setting 

 

 

 

 

 

 

Switch Between F/C 

6.  Switch Between F/C 

 

 

 

 

 

 

Temperature Calibration 

7. Temperature 

Calibration 

 

 

 

 

 

 

5.1 Press the (-) button for 4 seconds, “counter” 

lights located in the display will illuminate 

indicating you are in the adjust counter 

setting mode.   

5.2 Next, press the (-) button to lower the 

value ,or press the (+) button to raise the 

value .The counter setting range can be set 

from 0~99999. 

 

6.1 Press and hold the (+) button then press 

model select button, “F-C” lights located in 

the display will illuminate indicating you are 

in the adjust F-C setting mode.   

6.2 Press the (-) button and (+) button to switch 

between Fahrenheit and Celsius   

 

 

7.1    Press and hold the (-) button then press 

model select button, “Pb” lights located in 

the display will illuminate indicating you are 

in the adjust temperature calibration mode.   

7.2    press the (-) button to lower the value ,or 

press the (+) button to raise the value. 

Содержание GS-202

Страница 1: ...xamination and repair Incorrect assembly or repair could increase the risk of fire electric shock or injury to persons when the equipment is used 7 This appliance is not intended for use by persons in...

Страница 2: ...5 Operating Instructions 6 9 Connecting the System 6 Turning the System On 6 Adjusting the Temperature 7 Adjusting the Time 7 Counter Setting 8 Switch Between F C 8 Temperature Clibration 8 Adjusting...

Страница 3: ...oz 15oz etc mug 12oz Latte shape mug heater 17oz latte shape mug heater Power 120volt 300W 2 7Amps 300W 2 7Amps Power 240volt 300W 1 4Amps 300W 1 4Amps Temperature Range Max 200 392 Max 200 392 Time R...

Страница 4: ...4 Machine View...

Страница 5: ...5 Control Panel Guide...

Страница 6: ...be as short as possible and not less than 12 gauge Heavy duty cords are recommended CIRCUITS that have less than 10 amps or that have other high demand equipment or appliances especially more than one...

Страница 7: ...e Control Panel the second time TEMPERATURE 2 lights located in the display will illuminate indicating you are in the adjust temperature mode 3 4 Next press the button located to the bottom of the Mod...

Страница 8: ...he value The counter setting range can be set from 0 99999 6 1 Press and hold the button then press model select button F C lights located in the display will illuminate indicating you are in the adju...

Страница 9: ...uipment has reached the designated temperature1 position the blank mug inside and proceed to press 6 2 After pressure handle closed heater will heat up from temperature1 to temperature 2 then time sta...

Страница 10: ...02 1 3 M6 18 10 Handle Screw 1000569 1 4 GSB 03 Metal sheet 1000018 1 5 CG 03 Holding Block 1000017 1 6 GB 01 Holding Base 1000015 1 7 GB Y102 Heater Cover 1000019 1 8 MC 0627 Magnet switch 1800620 1...

Страница 11: ...over 1200446 1 18 8A L1080271504 01 Fuse 1800348 1 19 GSK G03 Circuit Breaker 1800354 2 20 RK1 01 On off switch 1800346 1 21 IEC DB 14 1 socket 1800344 1 22 TB1503L Terminal Block 1800345 1 23 DX146 1...

Отзывы: