20
Heat Pump Installation Guide
Placement
•
Refer to the foundation requirements
page.
•
All our swim spas (excluding the Calypso
Minor) come pre-plumbed with the heat
pump unions. Refer to the schematic
layouts to see where the Heat Pump
unions are positioned.
2500mm
500mm
500mm
1200mm
Required Materials
•
40mm PVC pressure pipe - enough to suit
the plumbing configuration of where your
heat pump sits in relation to the Swim Spa.
•
40mm hole saw for cabinet drilling
•
Hacksaw
•
PVC pipe cement
Installation
1
Ensure power is off and remove cabinet
where heat pump connection sits.
2
Decide where the plumbing will come in
through the cabinet and drill 2 x 40mm
holes to accommodate the input and
output of the heat pump piping.
3
Close the two shut-off valves at either end
of the heat pump unions.
4
Plumb the correct unions from the heat
pump to the swim spa.
5
Purge air from the heat pump by loosening
the outlets until water starts to drip, then
tighten back up.
6
Connect the power cable from the heat
pump into one of the 230V mains outlets
on the Gecko controller.
7
Connect the heat pump data cable to the
EXP2 data socket of the Gecko controller.
8
Restore power to the swim spa, and turn
on jets to ensure the water is flowing and
free of air locks.
9
Use the Spa Choice manual to set user
controls for heat pump and set how it
works with the variable heater.
OUTLET
INLET
300MM
DATA
CABLES
CIRC
PUMP
MAIN CIRCULATION LINE
OFF SHOO
T
OUTLET
SLICE
VALVES
OFF SHOO
T
INLET
Spa Choice
IN.YE5+IN.K806+3KW
Содержание SWIM SPA
Страница 1: ...SWIM SPA PRE DELIVERY GUIDE...
Страница 4: ...4...
Страница 13: ...13 CALYPSO MINOR 500mm Service Area Control Panel Drain Valve Control Box...
Страница 24: ...24 Scale 5m Sq Notes...
Страница 25: ...25 Scale 5m Sq...
Страница 26: ...0800 459 772 galaxyspas co nz GS0001 0862021...