21
2. The heating system is not heated
(is slightly heated).
High specific electric resistance of
water. The specified heat-transfer
agent temperature is lower than the
required temperature.
Boiler connection diagrams and
radiators installation diagrams do
not correspond to the diagrams
described in the given Operation
manual.
Pay scrupulous attention to the
recommendations of the given
Operation manual for the heat-
transfer agent.
Increase the specified temperature
of the heat-transfer agent.
Put the connection and installation
diagrams into correspondence with
the diagrams described in the given
Operation manual.
Presence of air locks in the heating
system because of incorrect
installation. Power of the boiler does
not correspond to the power of the
connected heating devices
(radiators, convectors, etc.).
Correct the mistakes in the boiler
installation. Fill the heating system
with heat-transfer agent through the
drain valve under pressure. Put the
power of the boiler into
correspondence with the power of
the connected heating devices.
3. The boiler consumes nominal
power but only the standpipe is
heated.
Disruption of the heat-transfer
agent circulation.
Presence of air locks in the heating
system.
Clean the heating system. Wash it
carefully by means of the “Galan-
Protektor” rust inhibitor.
Usage of the strainer is mandatory.
It is necessary to clean the strainer
periodically.
Remove the air locks.
4. In due course, the boiler wastes
its power gradually (under condition
of using “fresh water”).
Presence of contamination, rust, and
scale on the electrodes and on the
internal surfaces of the boiler.
Give the electrodes and the internal
surfaces of the boiler case a mirror-
like polish.
Guarantee commitments
1.
The guarantee period of operation comprises 12 months from the date of
sale.
2.
The boiler life comprises 10 years (under condition of the correct boiler
operation in accordance with the given Operation manual and periodical
(every 3-5 years) replacement of the electrodes).
3.
The guarantee commitments are applied to the boiler which is installed by the
specialized organization which has contractual relationships with the
manufacturer (under condition of obligatory filling of the boiler installation
coupon).
4.
The guarantee commitments are applied to the boiler during the course of
guarantee period of operation. The operation and preventive maintenance are
performed in accordance with the given Operation manual.
5.
The manufacturer does not bear responsibility for the boilers operation in the
following cases:
•
The heating and electric diagrams do not correspond to the diagrams
specified in the given Operation manual;
•
The boiler is purchased without automatic control system recommended
by the “Firma “GALAN” Joint-Stock Company;
•
The boiler has mechanical damages;
•
The boiler worked at the temperatures exceeding the temperatures
recommended by the given Operation manual or by means of the heat-
transfer agents which are not recommended by the “Firma “Galan” Joint-
Stock Company.