![GALA SPA YARD Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/gala/spa-yard/spa-yard_user-manual_558039019.webp)
19
SPA YARD
2.5.3. LEVEL SENSOR
The function of the level sensor is to detect the water level and prevent the pumps from starting in the
absence of water.
WARNING:
T
he ice prevention cycle will be performed even though the level sensor does not detect the presence of
water inside the Spa (if there is any residual water inside the pipes).
2.5.2. HI-LIMIT SENSOR
The function of the HI-LIMIT sensor is to control the heater temperature so that it may be deactivated in
the following case:
2.5. ALARMS
This section describes the alarms that the control panel can detect and display to the user by means of a
signal on the keypad display.
2.5.1. PRESSURE SWITCH
There are two conditions:
The pressure switch function controls the water flow through the heater.
ALARM CONDITION
DISPLAY
INDICATION
SUPPRESSED
FUNCTIONS
CONDITIONS TO
STOP THE ALARM
DISPLAY INDICATION
DISPLAY
INDICATION
SUPPRESSED
FUNCTIONS
CONDITIONS TO
STOP THE ALARM
ALARM CONDITION
DISPLAY
INDICATION
SUPPRESSED
FUNCTIONS
CONDITIONS TO
STOP THE ALARM
The pressure switch indicates the
presence of a water flow when
there should be none.
(heating pump on)
The pressure switch indicates a
lack of water flow when there
should be one (heating pump on).
Heater
Heater
Restoration
Restoration
Detected temperature
(Hi-Limit sensor
≥
48ºC.)
The temperature drops
to below 44º C and the
control panel starts up
(power supply on/off).
Heater
HOH
alternating between
the time and the
water temperature
inside the Spa.
Water level below the
level sensor
H2O
Pumps, heater, air
jet and spotlight
The water level is restored
and this is detected by the
sensor