30 / 50 KVA
45
5
1
4
2
3
R
M
V1
V2
C
A
B
B
A
P
3 - INSTALATION
Following cares must be taken when installing spot welding
machines:
Arms, electrode holders and electrodes water cooling system
tubes must be connected to the main water supply, or other closed
water cooling system. Water pressure must not exceed 2 Kg/cm2
and the flowing rate must be adjusted according to electrode
temperature (<50º C).
CLOSED WATER COOLING SYSTEM
On pneumatic machines, compressed air system must be provided with a lubricating and filtering set. In order to
obtain the adequate filter, please contact your distributor. Air pressure must not exceed 8 Kg/cm2.
PNEUMATIC SCHEMA
A - Ascending movement ( positive )
B - Descending movement ( negative )
C - Pneumatic cylinder diam. 50 - 100
M - Air pressure manometer
R - Air pressure regulator
V1 - Command valve (pedal)
V2 - Air flow regulator
COOLING CIRCUIT
* WATER IN
- Inlet cold water
** WATER OUT
– Outlet hot water