P
UB
42004-438A
300
S
ERIES
E
MERGENCY
T
ELEPHONE
M
ANUAL
P
AGE
22 of 44
f:\standard ioms - current release\42004 instr. manuals\42004-438a.doc
02/11
Password Enable Configuration
Factory Setting
: Password Enabled
This telephone can be configured to enable or disable the password protection for programming. This can
be useful when initially programming the telephones.
Password Enabled
: J9 jumper on pins 2 and 3.
Password Disabled
: J9 jumper on pins 1 and 2.
Command Select Configuration
Factory Setting
: Auto
The purpose of J20 is to enable or disable automatic transition to SMART operation. With this jumper in
the standard position, SMART operation is disabled.
SMART Operation Enabled (Auto)
: J20 jumper on pins 2 and 3.
SMART Operation Disabled (Standard)
: J20 jumper on pins 1 and 2.
Hardware Settings
Table 3. Hardware Settings Table
Default Settings
User Settings
Function Setting
Jumper/Position
Setting
Jumper/Position
Auto-answer
Enabled
J14/3 & 2
Password Protection
Enabled
J9/3 & 2
Line Polarity
Non-polarized
J6/3 & 2
Command Select
Auto
J20/2 & 3
DTMF Gain Select
Low Gain
J17/1 & 2
Auxiliary Outputs
Each telephone includes two isolated solid state switches capable of switching a maximum of 48 V dc,
125 mA or 28 V
RMS
ac, 80
RMS
mA. TB2 (OUT1) and TB5 (OUT4) on the emergency phone PCBA
provides the connections for the auxiliary outputs. Refer to Figure 23 for the location of TB2 and TB5.
Refer to the “Auxiliary Output Control” section on page 28 for additional information.