background image

Pub. 42004-520A 

NEMA 4X VoIP Telephones 

Page 3 of 15 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-520A.docx 
03/17 

Feature and Functions 

GAI-Tronics VoIP telephones include the following features: 

 

NEMA 4X rated with door closed (NEMA 3R with door open) 

 

Handset with 6-foot Hytrel coiled cord and noise-cancelling microphone 

 

Panel-mounted push-button volume control 

 

Chrome-plated keypad with protective rubber boot and braille reference 

 

Brushed stainless steel panel 

 

Stainless steel assembly hardware. 

 

SIP compatible (RFC3261) 

 

Real-time alarm reporting via email or syslog 

 

Power-over-Ethernet compatible (Power Mode A, Class 0) 

 

Configurable via web page, serial link or download 

 

Four configurable auxiliary inputs and two configurable voltage-free contact outputs 

Installation Guidelines 

ATTENTION

  Installation should be performed by qualified personnel and only in 

accordance with the National Electrical Code or applicable local codes. 

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to 
ensure the safety of all personnel: 

 

NEVER install telephone wiring during a lightning storm. 

 

Install a UL Listed lightning arrestor

 on any telephone installed where the telephone or telephone 

cable is at risk of being exposed to lightning strikes.  The lightning arrestor must be installed as close 
to the telephone as possible to maximize the protection.  The lightning arrestor must not be installed 
within the enclosure supplied with the telephone. 

 

NEVER install telephone jacks in wet locations unless the jack is specifically designed for wet 
locations. 

 

NEVER touch uninsulated telephone wires or terminals unless the telephone line has been 
disconnected at the network interface. 

 

USE CAUTION when installing or modifying telephone lines. 

 

Install a UL Listed telephone line suppressor (customer-supplied) on the telephone line. 

 

Use silicone sealant or equivalent around and inside of all conduit entries 

 

Install a Cat5 data line lightning surge protector

 on any phone installed where the phone or phone 

cable is at risk of being exposed to lightning strikes.  The lightning arrestor must be installed as close 
to the phone as possible in a non-hazardous environment.  The lightning arrestor must not be installed 
within the telephone enclosure. 

 

USE CAUTION when installing or modifying Category 5 data lines. 

Содержание 354-700

Страница 1: ...o ideal for use in areas that require a direct water spray hose down for cleaning purposes or where a non corrosive material is required The 354 70x Series Telephone is perfectly suited for areas cons...

Страница 2: ...to peer configuration without the need for a LAN however a 10 100 Base T Ethernet network with a Sessions Initiation Protocol SIP server is required for systems containing three or more VoIP telephone...

Страница 3: ...nnel NEVER install telephone wiring during a lightning storm Install a UL Listed lightning arrestor on any telephone installed where the telephone or telephone cable is at risk of being exposed to lig...

Страница 4: ...it Security Hardware The Model 354 70x Series Telephone is vandal resistant with the front panel attached to its enclosure with security screws A GAI Tronics Model 233 001 Security Screwdriver sold se...

Страница 5: ...holes located on the mounting flanges with 3 8 inch M8 hardware The recommended entry is via the enclosure bottom to prevent moisture from dripping onto the connection terminals When mounting the encl...

Страница 6: ...l push button and ringer The handset rests on a cradle which has a magnetic reed switch to signal an off hook condition See Figure 3 Figure 3 NEMA 4X VoIP Telephone Internal The Model 354 70x NEMA 4X...

Страница 7: ...Figure 5 This configuration presents the easiest access for troubleshooting and setting adjustments 2 Plug the incoming Cat5 data line to the network RJ45 cable jack on the underside of the VoIP circu...

Страница 8: ...2 6 COM Common 7 IN1 Input 1 8 COM Common Inputs have an internal pull up resistor and need to be 3 3 V dc tolerant Outputs Two outputs have been provided for customer use Terminations for these outp...

Страница 9: ...WG is typical Status Indication Power The power LED located on the VoIP PCBA illuminates when power is applied to the telephone Refer to Figure 7 for the location Heartbeat The heartbeat LED located o...

Страница 10: ...13 1 36 Nm External Controls Handset ReceiverVolumeControl A push button switch is provided on the front panel for adjustment of the handset receiver volume When pressed it decreases the volume gain f...

Страница 11: ...for the network prior to installation Assign a local ID domain proxy and registrar Assign a host name The host name provides identification of the different VoIP PCBAs on the network Test Verify that...

Страница 12: ...ndset on hook Monitoring and Reporting Each telephone can recognize and generate several hardware and configuration fault condition alarms These alarms can be signaled to a remote site using three met...

Страница 13: ...uts not operational Check the output connections Verify the outputs are properly configured Cannot make or receive calls Check the connection of the LAN cable Verify that power is applied to the unit...

Страница 14: ...dB Analog earpiece gain Default 20 dB Setting 2 12 dB Setting 3 0 dB Frequency response 250 Hz to 6500 Hz Frequency response flatness 3 dB minimum THD 1 kHz 1 minimum Inputs Keypad 3 4 matrix Push but...

Страница 15: ...User Instructions USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonab...

Страница 16: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: