Model 226-002 

Mounting and wiring of the Model 226-002 must be in accordance with Div. 2 installation standard 
practices. 

1.

 

Use a GAI-Tronics Model 233-001 Screwdriver to loosen the eight front panel security screws. 

2.

 

Remove the front panel assembly to expose the eight mounting holes.  These holes accept 3/8-inch 
diameter bolts.  The length of these bolts depends on the mounting surface. 

 

For wider and retrofit hole patterns from the Northern Telecom Model NE-2525Q Series

, use the 

7.875 

 4.00-inch hole pattern.  Four hole plugs are supplied for the unused holes. 

When using the Model 232-001 Pole Mounting Kit

, use the 5.25 

 4.00-inch hole pattern.  This kit 

includes four 3/8-16 

 1-inch shoulder bolts with Teflon™ seal washers.  For additional support 

in wood poles, use 3/8-inch or 1/2-inch lug bolts with washers (not included). 

 

For wall-mount applications

, mount directly to the wall or use Model 232-001 Pole Mounting Kit 

and 3/8 inch or 1/2 inch lug bolts with washers.  (

N

OTE

:

 Lug bolts with washers are not included 

in the kit). 

3.

 

A 1/2-NPT conduit entrance is provided at both the top and the bottom of the unit.  An Allen drive 
plug is supplied for the unused entry. 

 

Figure 3.  Model 226-002 Outline Drawing 

Содержание 226-002

Страница 1: ...L E O F C O N T E N T S Confidentiality Notice 1 General Information 1 Installation Guidelines 1 User Instructions USA 3 User Instructions Canada CP 01 Issue 8 Part I Section 14 1 3 CP 01 Issue 8 Part...

Страница 2: ...re too harsh for a standard telephone The telephones operate the same as a standard telephone simply lift the handset and dial the desired telephone number The telephones are fully line powered and do...

Страница 3: ...tom conduit entry makes water less likely to enter the unit at the conduit connection points 4 Use Teflon pipe joint tape or a thread sealing compound around the conduit threads to seal threaded conne...

Страница 4: ...m is resolved This equipment uses the following USOC jacks RJ11CIt is recommended that the customer install an ac surge arrester in the ac outlet to which this device is connected This is to avoid dam...

Страница 5: ...g a lightning storm A Cat5 data line lightning surge protector is recommended for telephones subject to any electrostatic discharge e g lightning Do not install jacks in wet locations unless the jack...

Страница 6: ...STRIAL TELEPHONES PAGE 5 of 14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 Figure 1 Bottom entry conduit installation details RECOMMENDED for non metallic enclosures Figur...

Страница 7: ...patterns from the Northern Telecom Model NE 2525Q Series use the 7 875 4 00 inch hole pattern Four hole plugs are supplied for the unused holes When using the Model 232 001 Pole Mounting Kit use the 5...

Страница 8: ...nect the free end of the modular telephone cord to the incoming subscriber line using the appropriate mating connector or connect the incoming line directly to the terminal strip 5 Replace the front p...

Страница 9: ...t the enclosure to the wall using either four 1 4 20 machine screws with nuts and washers or 14 wood screws of appropriate length for the mounting surface Refer to Figure 7 3 Enter the rear enclosure...

Страница 10: ...ub 42004 339F MODEL 226 002 341 001 AND 351 001 DIV 2 INDUSTRIAL TELEPHONES PAGE 9 of 14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 Figure 7 Model 341 001 Mounting Diagra...

Страница 11: ...t 4 Pull on the left side of the enclosure until the hinge plugs pull loose to separate the front half from the rear half Set the front half of the enclosure aside 5 Mount the enclosure on the wall us...

Страница 12: ...14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 9 Close the front half of the enclosure and secure it by replacing the four outermost screws 10 Check for proper telephone o...

Страница 13: ...up To save the volume control setting jumper J4 which is factory set at positions 2 and 3 must be moved to positions 1 and 2 Specifications Electrical Typical Frequency response 300 to 3 000 Hz Inter...

Страница 14: ...e switch Connections 6 5 foot 1 98 m modular line cord Dimensions outside 8 0 W 9 5 H 6 9 D inches 204 242 174 mm Mounting Four 0 280 inch diameter holes Weight 6 0 lbs 2 7 kg Model 351 001 Mechanical...

Страница 15: ...ndset Assembly with 15 inch Armored Cord Volume Control and Noise Canceling 12512 001 Proximity Detecting Hookswitch Cradle Kit 12512 002 Hookswitch Cradle Kit 12516 001 Replacement Mounting Screw Kit...

Страница 16: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: