Installation 

WARNING

 

This product can contain hazardous voltages.  Always remove power to this 

station and any associated equipment before beginning any installation. 

CAUTION

Do not install this equipment in areas other than those indicated on the 

approval listing in the “Specifications” section of this manual.  Such installation may cause a safety 
hazard and consequent injury or property damage.

 

Install equipment without modification and according to all applicable local and national electrical codes.  
Consult the National Electrical Code (NFPA 70), Canadian Standards Association (CSA 22.1), and local 
codes for specific requirements regarding your installation.  Class 2 circuit wiring must be performed in 
accordance with NEC 725.55. 

Safety Guidelines 

When installing any GAI-Tronics equipment, please adhere to the following guidelines to ensure the 
safety of all personnel: 

 

Do not install wiring during a lightning storm. 

 

A Cat5 data line lightning surge protector is recommended for telephones subject to any electrostatic 
discharge (e.g. lightning) 

 

Do not install jacks in wet locations unless the jack is specifically designed for wet locations. 

Security Hardware 

The Model 226-002 is vandal-resistant, with the front panel attached to its enclosure with security screws.  
A GAI-Tronics Model 233-001 Security Screwdriver or Torx T-25 security head tip (sold separately) is 
recommended for installing the security screws.  Models 341-001 and 351-001 Telephones’ front panels 
are attached with standard Phillips head screws. 

Conduit Installation Details (applicable to Models 341-001 & 351-001) 

GAI-Tronics recommends installing telephone lines in conduit to protect against accidental damage and 
vandalism and to meet applicable Div. 2 installation requirements.  To prevent moisture from entering the 
enclosure, we strongly recommend the following: 

 

Conduit should enter the enclosure from the bottom. 

 

If entered from the top, the conduit must be internally sealed to prevent moisture ingress. 

 

Sealed fittings should be installed at all cable entry points. 

 

Silicone sealant or equivalent must be applied around and inside all conduit entries. 

Please refer to Figure 1 and Figure 2. 

Содержание 226-002

Страница 1: ...L E O F C O N T E N T S Confidentiality Notice 1 General Information 1 Installation Guidelines 1 User Instructions USA 3 User Instructions Canada CP 01 Issue 8 Part I Section 14 1 3 CP 01 Issue 8 Part...

Страница 2: ...re too harsh for a standard telephone The telephones operate the same as a standard telephone simply lift the handset and dial the desired telephone number The telephones are fully line powered and do...

Страница 3: ...tom conduit entry makes water less likely to enter the unit at the conduit connection points 4 Use Teflon pipe joint tape or a thread sealing compound around the conduit threads to seal threaded conne...

Страница 4: ...m is resolved This equipment uses the following USOC jacks RJ11CIt is recommended that the customer install an ac surge arrester in the ac outlet to which this device is connected This is to avoid dam...

Страница 5: ...g a lightning storm A Cat5 data line lightning surge protector is recommended for telephones subject to any electrostatic discharge e g lightning Do not install jacks in wet locations unless the jack...

Страница 6: ...STRIAL TELEPHONES PAGE 5 of 14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 Figure 1 Bottom entry conduit installation details RECOMMENDED for non metallic enclosures Figur...

Страница 7: ...patterns from the Northern Telecom Model NE 2525Q Series use the 7 875 4 00 inch hole pattern Four hole plugs are supplied for the unused holes When using the Model 232 001 Pole Mounting Kit use the 5...

Страница 8: ...nect the free end of the modular telephone cord to the incoming subscriber line using the appropriate mating connector or connect the incoming line directly to the terminal strip 5 Replace the front p...

Страница 9: ...t the enclosure to the wall using either four 1 4 20 machine screws with nuts and washers or 14 wood screws of appropriate length for the mounting surface Refer to Figure 7 3 Enter the rear enclosure...

Страница 10: ...ub 42004 339F MODEL 226 002 341 001 AND 351 001 DIV 2 INDUSTRIAL TELEPHONES PAGE 9 of 14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 Figure 7 Model 341 001 Mounting Diagra...

Страница 11: ...t 4 Pull on the left side of the enclosure until the hinge plugs pull loose to separate the front half from the rear half Set the front half of the enclosure aside 5 Mount the enclosure on the wall us...

Страница 12: ...14 e standard ioms current release 42004 instr manuals 42004 339f doc 07 14 9 Close the front half of the enclosure and secure it by replacing the four outermost screws 10 Check for proper telephone o...

Страница 13: ...up To save the volume control setting jumper J4 which is factory set at positions 2 and 3 must be moved to positions 1 and 2 Specifications Electrical Typical Frequency response 300 to 3 000 Hz Inter...

Страница 14: ...e switch Connections 6 5 foot 1 98 m modular line cord Dimensions outside 8 0 W 9 5 H 6 9 D inches 204 242 174 mm Mounting Four 0 280 inch diameter holes Weight 6 0 lbs 2 7 kg Model 351 001 Mechanical...

Страница 15: ...ndset Assembly with 15 inch Armored Cord Volume Control and Noise Canceling 12512 001 Proximity Detecting Hookswitch Cradle Kit 12512 002 Hookswitch Cradle Kit 12516 001 Replacement Mounting Screw Kit...

Страница 16: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: