Settings and Adjustments
The following settings and adjustments are made via the XAC1000A CARD Suite programming
software:
Mode:
•
Generic (default)
•
Selective
Coding:
•
DTMF (default)
−
Code (1-8 digits)
−
Alias (12 characters maximum)
•
2-Tone
−
A Tone duration (0.5 to 4.0 seconds, 0.5-second intervals)
−
B Tone duration (0.5 to 4.0 seconds, 0.5-second intervals)
−
A Tone, 280 to 2700 Hz, 0.1-Hz increments
−
B Tone, 280 to 2700 Hz, 0.1-Hz increments
−
Alias (12 characters maximum)
Standby Time:
0.5 to 12 seconds, 0.5-second intervals (default - 3 seconds)
Speaker Enable Mode:
•
On
•
Off (default)
Speaker Volume:
2 mW to 8 W (default 16 mW); 80 dB to 116db (default 89 dB)
Test Tone Length
Initial tone, 1 to 6 seconds, 0.5 second intervals (default – 3 seconds)
Following tones, 1 to 6 seconds, 0.5 second intervals (default - 3 seconds)
Refer to the CARD Suite Help (F1 or Help menu item) for further information on setting these