29
Fault
Possible cause
Remedial action
The ice maker is not producing enough
ice or the ice cubes are misshapen.
The water pressure is too low.
Check water pressure. The water
pressure must be between 25 and
120 p.s.i. (1.72–8.25 bar).
The freezer compartment temperature
is too low.
Check temperature of the freezer
compartment. If required increase
the temperature.
Change the water filter.
Instructions for changing the water
filter can be found in the section
"Water filter".
Ice is forming in the supply hose to the
ice maker.
The water pressure is too low.
Check water pressure. The water
pressure must be between 25 and
120 p.s.i. (1.72–8.25 bar).
The freezer compartment temperature
is too low.
Check temperature of the freezer
compartment. If required increase
the temperature.
Water is flowing out of the appliance.
Close shut-off valve immediately.
The water pipe in the appliance
is defective.
Call customer service immediately.
The water pressure is too low.
The valve may leak if the water
pressure is too low. The water pressure
must be between 25 and 120 p.s.i.
(1.72–8.25 bar).
A wrong water valve has been installed.
Self-tapping valves and
3
/
16
inch
(4.76 mm) saddle valves reduce the
water pressure and may eventually
block the pipe.