WARNING 

 

Avoiding General Hazards 

Do not use the dishwasher until it is completely 
installed. When opening the door on an uninstalled 
dishwasher, carefully open the door while 
supporting the rear of the unit. Failure to follow this 
warning can cause the dishwasher to tip over and 
result in serious injury. 

Before installing the “L”-shaped supplied countertop 
mounting brackets (select models), decide which 
method will be used to secure the dishwasher into 
its opening. Once these mounting brackets are 
installed on the dishwasher, removing them is 
difficult and will damage the mounting brackets and 
the dishwasher. 

In some conditions, hydrogen gas can form in a hot 
water system that has not been used for weeks. 
Hydrogen gas is explosive. 

Before filling a dishwasher from a system that has 
been off for weeks, run the water from a nearby 
faucet in a well ventilated area until there is no 
sound or evidence of gas. 

Temperatures required for soldering and sweating 
will damage the dishwasher’s base and water inlet 
valve. If plumbing lines are to be soldered or 
sweated, keep the heat source at least 6

Ǝ

 (152.4 

mm) away from the dishwasher’s base and water 
inlet valve. 

Removing any cover or pulling the dishwasher from 
the cabinet can expose hot water connections, 
electrical power and sharp edges or points. Handle 
with care. 

Avoiding Electrical Shock/Fire Hazards

 

Do not allow the electrical and water supply lines to 
touch. Separate channels are provided under the 
dishwasher. 

Do not work on an energized circuit. Doing so could 
result in serious injury or death. Only qualified 
electricians should perform electrical work. Do not 
attempt any work on the dishwasher electric supply 
circuit until you are certain the circuit is de-
energized. 

Make sure electrical work is properly installed. 
There should be no loose electrical connections. 
Ensure all electrical connections are properly made. 

The customer has the responsibility of ensuring that 
the dishwasher electrical installation is in 
compliance with all national and local electrical 
codes and ordinances. The dishwasher is designed 
for an electrical supply of 120V, 60 Hz, AC, 
connected to a dishwasher-dedicated, properly 
grounded electrical circuit with a fuse or breaker 
rated for 15 amps. Electrical supply conductors 
shall be a minimum #14 AWG copper only wire 
rated at 75°C (167°F) or higher. 

This appliance must be connected to a grounded 
metal, permanent wiring system, or an equipment-
grounding conductor must be run with the circuit 
conductors and connected to the equipment-
grounding terminal or lead on the appliance. Do not 
use extension cords. 

Avoiding Electrical Shock/Fire Hazards 

Do not perform any work on a charged hot water 
line. Serious injury could result. Only qualified 
plumber should perform plumbing work. Do not 
attempt any work on the dishwasher hot water 
supply plumbing until you are certain the hot water 
supply is shut off. 

Do not over tighten the 90° elbow. Doing so may 
damage the water inlet valve and cause a water 
leak. 

Temperatures required for soldering and sweating 
will damage the dishwasher’s water inlet valve. If 
plumbing lines are to be soldered or sweated, keep 
the heat source at least 6

Ǝ

 (152.4 mm) away from 

the dishwasher’s water inlet valve. 

Check local plumbing codes for approved plumbing 
procedures and accessories. All plumbing should 
be done in accordance with national and local 
codes. 

These instructions depict an installation method for 
stainless steel braided hose or PEX hot water 
supply lines. If using copper tubing or other material 
for water supply, defer to a licensed plumber for 
proper installation. 

 

Содержание KG 260 CA

Страница 1: ...9000 901 316 9311 Installation Instructions Notice d installation...

Страница 2: ......

Страница 3: ...ly and should not be used in commercial food service establishments x NEW INSTALLATION If the dishwasher is a new installation most of the work must be done before the dishwasher is moved into place x...

Страница 4: ...rtain the circuit is de energized Make sure electrical work is properly installed There should be no loose electrical connections Ensure all electrical connections are properly made The customer has t...

Страница 5: ...Cable Minimum 14 AWG 2 conductor 1 ground insulated copper conductors rated 75 C or higher Hot Water Supply Line Minimum 3 8 O D copper tubing or metal braided dishwasher supply line Shut off valve an...

Страница 6: ...4 Materials Supplied...

Страница 7: ...r supply lines to touch After locating the proper place for your new dishwasher you will need to create any required openings to allow for passage of the water drain and electrical line In order to av...

Страница 8: ...uctors and connected to the equipment grounding terminal or lead on the dishwasher Make sure that the dishwasher is connected to a suitable ground in compliance with all local codes or in the absence...

Страница 9: ...ter that is too hot can cause some detergents to lose effectiveness Lower water temperatures will increase run times The hot water supply pressure must be between 15 145 psi 1 10 bar IMPORTANT NOTES x...

Страница 10: ...need to be supported It is best to lay the end on the cabinet floor as shown in Figure 9 4 After all connections are made turn on the hot water and check for leaks Drain Connections The dishwasher dr...

Страница 11: ...ning width measures 235 8 600mm use the TOP or SIDE MOUNT mounting methods If your dishwasher opening width measures 235 8 600 mm use the ALTERNATE SIDE MOUNT mounting method Top Mount is used for cou...

Страница 12: ...nd the unit or kink as you slide the unit back Make certain to slide the unit into place before raising the leg levelers Level the dishwasher horizontally by turning feet clockwise to raise or counter...

Страница 13: ...e Figure 26 4 For models with a three piece toe panel the rubber apron removed earlier may now be attached and should remain behind the outermost toe panel 5 For models with outer toe panel 3rd piece...

Страница 14: ...se take the following steps in the order listed below until the problem is corrected to your satisfaction 1 Contact your installer or the Authorized Service Contractor in your area 2 E mail us See you...

Страница 15: ...e uniquement et ne doit pas tre utilis par des tablissements de service alimentaire commerciaux x NOUVELLE INSTALLATION Si le lave vaisselle est install pour la premi re fois la plupart des travaux d...

Страница 16: ...certain que celui ci est hors tension V rifier que l installation lectrique est correctement r alis e Il ne doit y avoir aucun raccordement lectri que l che V rifier que tous les branchements lectri q...

Страница 17: ...s 1 mise la terre conducteurs en cuivre isol une temp rature nominale de 75 C ou plus Tuyau d alimentation d eau chaude tube de cuivre de 3 8 po minimum diam tre ext rieur ou tuyau d alimentation pour...

Страница 18: ...16 Mat riel fourni...

Страница 19: ...iques et les tuyaux d alimentation d eau ne doivent pas entrer en contact les uns avec les autres Apr s avoir trouv l emplacement ad quat pour installer votre nouveau lave vaisselle vous devez pr voir...

Страница 20: ...rre ou un conducteur de mise la terre du mat riel doit tre utilis avec les conducteurs du circuit et rac cord la borne de mise la terre de l appareil ou au fil conducteur du lave vaisselle S assurer q...

Страница 21: ...re de l eau est trop basse la dur e de lavage sera plus longue La pression d alimentation d eau chaude doit tre comprise entre 15 et 145 psi 1 et 10 bars REMARQUE x En cas d utilisation d un joint de...

Страница 22: ...re comme indiqu sur la Figure 9 4 Une fois tous les raccordements effectu s ouvrir le robinet d eau chaude et v rifier s il y a des fuites Raccordements d vacuation Le tuyau de vidange du lave vaissel...

Страница 23: ...l ouverture de votre lave vaisselle est sup rieure 235 8 po 600 mm utilisez les m thodes de MONTAGE PAR LE DESSUS ou LAT RAL Si la largeur de l ouverture de votre lave vaisselle est inf rieure 235 8...

Страница 24: ...de l appareil Veiller mettre l appareil en place avant de relever les v rins de calage Mettez le lave vaisselle de niveau l horizontale en tournant les v rins dans le sens des aiguilles d une montre...

Страница 25: ...dot s d un panneau de plinthe en trois parties le tablier de caoutchouc retir pr c demment devra tre remis en place ce stade en veillant ce qu il reste derri re la partie la plus loign e du panneau de...

Страница 26: ...lez effectuer les tapes suivantes dans l ordre indiqu ci apr s jusqu ce que le probl me soit r solu votre enti re satisfaction 1 Communiquez avec votre installateur ou avec le prestataire de service a...

Страница 27: ......

Страница 28: ......

Отзывы: