Gaggenau AH600990 Скачать руководство пользователя страница 5

1.2 Operating for the first time

Before operating the appliance for the first time,
please pay attention to the following notes:

The appliance 

must be installed and connected

by a specialist before it is operated for the first
time.

The rating plate

for this appliance is included

with the instructions on a separate sheet. Store
the rating plate in the same location as your
operating and assembly instructions. You need
the rating plate for possible damage and
warranty cases.

Conscientiously read

through the operating

and assembly instructions before operating the
appliance for the first time.

Remove the packaging

from the appliance and

dispose of it properly. Pay 

attention 

to the fact

that there are accessories in the packaging.
Keep packaging elements out of the reach of
children!

Thoroughly clean

the appliance before using it

for the first time. (see chapter entitled “Cleaning
and care”).

Before operating

the appliance for the first

time, check that the mains connection is in
proper working order.

1.3 About use

The appliance is intended

solely for use in the

household and must not be put to any other uses.

In the event of malfunctions

, first of all check

the household fuses. If the problem has nothing
to do with the power supply, please contact your
specialist dealer or your local Gaggenau after-
sales service.

4

Содержание AH600990

Страница 1: ...Operating and Assembly Instructions AH 600 990 Coanda Extractor Hood 0 0 1 2 3...

Страница 2: ...ing principle Page 5 6 2 1 Structure of the appliance Page 5 2 2 Accessories special accessories Page 5 2 3 Operating principle Page 6 3 Operation Page 7 8 3 1 Switching on and off Page 7 3 2 Special...

Страница 3: ...the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on...

Страница 4: ...th water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the correspon ding fus...

Страница 5: ...ng the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out...

Страница 6: ...key 6 Ventilation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda leve...

Страница 7: ...rcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter T...

Страница 8: ...ny time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level...

Страница 9: ...the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to...

Страница 10: ...maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in...

Страница 11: ...he two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in th...

Страница 12: ...ender all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease fil...

Страница 13: ...rved when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm The wall hood was conceived fo...

Страница 14: ...n Air recirculation You need the following accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your d...

Страница 15: ...holes for the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the includ...

Страница 16: ...op of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fi...

Страница 17: ...the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels...

Страница 18: ...the 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pul...

Страница 19: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 81739 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...

Отзывы: