Proceed as follows:

Exhaust air operation:

– From the bottom edge of the hood, mark a center

line on the wall. 

– With the aid of the drilling template, mark the

positions of the screws on the wall. Mark the
contour of the hook-in area. This will make it
easier to hook in the hood (Fig. 18).

– Pay attention to the minimum clearance of 600 mm

for electric cookers and 670 mm for gas cookers.
The bottom edge of the template corresponds to
the bottom from edge of the hood.

– Using the drilling template, drill the 6 holes for

the hood (area I of the drilling template) and the
two holes for suspending the chimney (area II of
the drilling template). In the top two securing
holes for the hood, fix the two hooks

e

with the

countersunk screws 

d

. Make sure that the hooks

lie flatly on the wall. In certain circumstances you
may have to countersink the drill holes. Fit the
included dowels 

a

in the other drill holes. 

Note: 

Pay attention to any special accessories that

you may have to fit. 

– Screw on the retaining bracket for the chimney

paneling.

– Detach the grease filters.

– Unscrew the two black plates on the left and right

of the chimney.

– Hang the hood on the two hooks. Adjust the

suspended element with the recessed head
screw and align the hood using a spirit level 
(Fig. 19).

14

448

137

625

270

300

15

310

mind. 600 Elektro
mind. 670 Gas

230

Fig. 18

Fig. 19

min. 600 electric

min. 670 gas

Important: 

Before marking the securing holes,

make sure that no electricity or water lines or
other lines are laid at the drilling points in the wall.

Содержание AH600990

Страница 1: ...Operating and Assembly Instructions AH 600 990 Coanda Extractor Hood 0 0 1 2 3...

Страница 2: ...ing principle Page 5 6 2 1 Structure of the appliance Page 5 2 2 Accessories special accessories Page 5 2 3 Operating principle Page 6 3 Operation Page 7 8 3 1 Switching on and off Page 7 3 2 Special...

Страница 3: ...the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on...

Страница 4: ...th water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the correspon ding fus...

Страница 5: ...ng the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out...

Страница 6: ...key 6 Ventilation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda leve...

Страница 7: ...rcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter T...

Страница 8: ...ny time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level...

Страница 9: ...the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to...

Страница 10: ...maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in...

Страница 11: ...he two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in th...

Страница 12: ...ender all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease fil...

Страница 13: ...rved when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm The wall hood was conceived fo...

Страница 14: ...n Air recirculation You need the following accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your d...

Страница 15: ...holes for the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the includ...

Страница 16: ...op of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fi...

Страница 17: ...the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels...

Страница 18: ...the 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pul...

Страница 19: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 81739 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...

Отзывы: