CompuScope 1220 product introduction 

CompuScope 1220 is 12 bit dual channel, 20 MS/s waveform digitizer card for the PCI Bus. 

Recognizing that until very recently, almost all multi-Megahertz data acquisition was done using Digital Storage 
Oscilloscopes under GPIB control, Gage has ported all the features of these DSOs onto the CompuScope card.  
This means that you do not have to rethink the solution in terms of a completely unknown data acquisition card.  
You can simply develop the data acquisition system as if an oscilloscope were being used, but instead use a 
CompuScope card to take advantage of its attractive price and performance. 

Of course, CompuScope cards are much more than just another DSO under GPIB control:  

• 

CS1220 features up to 1 billion samples of on-board acquisition memory. 

• 

Multi-card Master/Slave systems provide from 2 to 16 channels of simultaneous A/D conversion, something 
normal DSOs simply cannot do. 

• 

Data transfer rates from CompuScope memory to PC memory run as high as 50 MB/s for the CS1220 as 
compared to a few hundred KB/s for GPIB. 

• 

CompuScope cards are easier to program, as Software Development Kits are available for C/C++, 
MATLAB and LabVIEW. 

• 

CompuScope cards are installed inside the PCI bus chassis, so there is no external box such as a DSO. 

• 

CS1220 cards have standard features such as Multiple Record, which help optimize the use of the on-board 
memory by stacking data from successive bursts. 

• 

You can also write software for a multi-card system in which all the cards are not in a Master/Slave 
configuration.  Drivers supplied by Gage support all these multi-card configurations. 

Special features of the CompuScope 1220 include: 

• 

Bus Mastering 

CompuScope 1220 cards are fully capable of becoming a bus master in order to transfer data at the 
maximum rate of 50 MB/s. 

A bus Master is a card that can take control of the bus and transfer data to any PCI target device such as 
system RAM without any involvement from the CPU. 

• 

External Clock 

CompuScope 1220 comes standard with External Clocking capability that allows synchronization of the 
digitizers with an external system. 

 

Содержание CompuScope 1220

Страница 1: ...GAGE APPLIED TECHNOLOGIES CS1220 Hardware Manual Reorder MKT HWM PCI01 CS1220 0408...

Страница 2: ...The installation program used to install the GageScope Software InstallShield is licensed software provided by InstallShield Software Corp 900 National Parkway Ste 125 Schaumburg IL InstallShield is C...

Страница 3: ...20 4 CompuScope 1220 compliance statement 7 CompuScope 1220 product introduction 8 CompuScope 1220 specifications 9 CompuScope 1220 ordering information 13 CompuScope 1220 simplified block diagram 14...

Страница 4: ...ompuScope 1220 card If you purchased a CompuScope 1220 4M or CompuScope 1220 8M card you should see a piggyback memory board attached to the back of the card as shown below If you purchased a CompuSco...

Страница 5: ...e Note that some packages will only be available if you have purchased the software and have a key provided by Gage CompuScope Certificate of NIST Traceable Calibration Each CompuScope card is shipped...

Страница 6: ...er Slave Timing Module is used for 4 Card Master Slave system of CS1220 1M 2 Card Master Slave system of CS1220 4M or CS1220 8M 8 Slot Master Slave Timing Module 8 Slot Master Slave Timing Module is u...

Страница 7: ...l Fast Transient Burst Immunity Performance criterion B IEC61000 4 5 Power Line Surge Immunity Performance criterion B IEC61000 4 6 Conducted RF Immunity Performance criterion A IEC61000 4 11 Voltage...

Страница 8: ...es from CompuScope memory to PC memory run as high as 50 MB s for the CS1220 as compared to a few hundred KB s for GPIB CompuScope cards are easier to program as Software Development Kits are availabl...

Страница 9: ...ts Acquisition Memory Worst Case Typical 1M 25 0 W 17 5 W 4M 28 0 W 20 5 W 8M 28 0 W 20 5 W 64M 32 5 W 23 5 W 256M 32 5 W 23 5 W 512M 32 5 W 23 5 W 1G 32 5 W 23 5 W Note Power connector on the deep me...

Страница 10: ...of 95 of full scale on the 1 V range Typical values listed below SNR 55 dB SFDR 57 dB ENOB 8 9 bits ACQUISITION MEMORY Data Storage In on board memory Memory sizes 1 Msamples 4 Msamples 8 Msamples 64...

Страница 11: ...a 64 point resolution Maximum Number of Triggers 4 194 304 MULTI CARD SYSTEMS Operating modes Master Slave or Multiple Independent Maximum Number of Cards Master Slave 2 to 8 cards for 1M memory 2 3 o...

Страница 12: ...nced analysis tools except for Extended Math Professional Edition Provides full functionality of all advanced analysis tools SOFTWARE DEVELOPMENT KITS SDK CompuScope SDK for C C For Windows 98 ME NT 2...

Страница 13: ...1 003 GageScope Software Product Order No GageScope Lite Edition Included GageScope Standard Edition purchased with CompuScope hardware 300 100 351 GageScope Standard Edition purchased independently 3...

Страница 14: ...14 CompuScope 1220 CompuScope 1220 simplified block diagram Figure 1 CS1220 simplified block diagram...

Страница 15: ...ad of the CompuScope card s own oscillator External Trigger BNC Connector used to input an analog or digital signal which may be used as an External Trigger External Trigger is defined exactly as in a...

Страница 16: ...note that much higher PRFs will be achieved using CompuScope Multiple Record mode The following test results were obtained using a computer configured as follows Pentium III 1 GHz processor 512 MB RAM...

Страница 17: ...CompuScope 1220 17 Notes...

Отзывы: