Gage CompuScope 1220 Скачать руководство пользователя страница 2

 

© Copyright Gage Applied Technologies 2004 

First Edition (August 2004) 

G

AGE

, C

OMPU

S

COPE

, and

 

G

AGE

S

COPE 

are registered trademarks of Gage Applied Technologies, Inc.  MS-DOS, W

INDOWS

 95, W

INDOWS

 

98, W

INDOWS

 ME, W

INDOWS

 NT, W

INDOWS

 2000 and W

INDOWS

 XP are trademarks of Microsoft Incorporated.  LabVIEW is a registered 

trademark of National Instruments.  MATLAB is a registered trademark of  The MathWorks Inc.  IBM, IBM PC, IBM PC/XT, IBM PC AT 
and PC-DOS are trademarks of International Business Machines Corporation.  All other trademarks are registered trademarks of their 
respective companies. 

Changes are periodically made to the information herein; these changes will be incorporated into new editions of the publication.  Gage 
Applied Technologies, Inc. may make improvements and/or changes in the products and/or programs described in this publication at any 
time.  The latest copy of this manual can be found on our web page at www.gage-applied.com in the Downloads section, User Manuals. 

Copyright © 2004 Gage Applied Technologies, Inc.  All Rights Reserved, including those to reproduce this publication or parts thereof in 
any form without permission in writing from Gage Applied Technologies, Inc.  The installation program used to install the GageScope 
Software, InstallShield, is licensed software provided by InstallShield Software Corp., 900 National Parkway, Ste. 125, Schaumburg, IL.  
InstallShield is Copyright ©1998 by InstallShield Software Corp., which reserves all copyright protection worldwide.  InstallShield is 
provided to you for the exclusive purpose of installing the GageScope Software.  In no event will InstallShield Software Corp. be able to 
provide any technical support for GageScope.  For detailed Terms and Conditions, please refer to the 

GageScope User’s Guide

Please complete the following section and keep it handy when calling Gage for 

technical support

Owned by: 

 

___________________________ 

Serial Number(s): 

___________________________ 

 ___________________________ 

Purchase Date: 

 

___________________________ 

Purchased From:   

___________________________ 

You must also have the following information when you call: 

·  Software Driver & Application Version 
·  Software Development Kit, if applicable 
·  Brand name and type of computer 
·  Processor and bus speed 
·  Total memory size 
·  Information on all other hardware in the computer 
 

How to reach Gage Applied Technologies for Product Support 

Toll-free phone:  (800) 567-GAGE 

Toll-free fax:  (800) 780-8411 

To reach Gage from outside North America 

Tel: (514) 633-7447   

Fax: (514) 633-0770 

 

Email

[email protected] 

Website

:  www.gage-applied.com 

 
 

Содержание CompuScope 1220

Страница 1: ...GAGE APPLIED TECHNOLOGIES CS1220 Hardware Manual Reorder MKT HWM PCI01 CS1220 0408...

Страница 2: ...The installation program used to install the GageScope Software InstallShield is licensed software provided by InstallShield Software Corp 900 National Parkway Ste 125 Schaumburg IL InstallShield is C...

Страница 3: ...20 4 CompuScope 1220 compliance statement 7 CompuScope 1220 product introduction 8 CompuScope 1220 specifications 9 CompuScope 1220 ordering information 13 CompuScope 1220 simplified block diagram 14...

Страница 4: ...ompuScope 1220 card If you purchased a CompuScope 1220 4M or CompuScope 1220 8M card you should see a piggyback memory board attached to the back of the card as shown below If you purchased a CompuSco...

Страница 5: ...e Note that some packages will only be available if you have purchased the software and have a key provided by Gage CompuScope Certificate of NIST Traceable Calibration Each CompuScope card is shipped...

Страница 6: ...er Slave Timing Module is used for 4 Card Master Slave system of CS1220 1M 2 Card Master Slave system of CS1220 4M or CS1220 8M 8 Slot Master Slave Timing Module 8 Slot Master Slave Timing Module is u...

Страница 7: ...l Fast Transient Burst Immunity Performance criterion B IEC61000 4 5 Power Line Surge Immunity Performance criterion B IEC61000 4 6 Conducted RF Immunity Performance criterion A IEC61000 4 11 Voltage...

Страница 8: ...es from CompuScope memory to PC memory run as high as 50 MB s for the CS1220 as compared to a few hundred KB s for GPIB CompuScope cards are easier to program as Software Development Kits are availabl...

Страница 9: ...ts Acquisition Memory Worst Case Typical 1M 25 0 W 17 5 W 4M 28 0 W 20 5 W 8M 28 0 W 20 5 W 64M 32 5 W 23 5 W 256M 32 5 W 23 5 W 512M 32 5 W 23 5 W 1G 32 5 W 23 5 W Note Power connector on the deep me...

Страница 10: ...of 95 of full scale on the 1 V range Typical values listed below SNR 55 dB SFDR 57 dB ENOB 8 9 bits ACQUISITION MEMORY Data Storage In on board memory Memory sizes 1 Msamples 4 Msamples 8 Msamples 64...

Страница 11: ...a 64 point resolution Maximum Number of Triggers 4 194 304 MULTI CARD SYSTEMS Operating modes Master Slave or Multiple Independent Maximum Number of Cards Master Slave 2 to 8 cards for 1M memory 2 3 o...

Страница 12: ...nced analysis tools except for Extended Math Professional Edition Provides full functionality of all advanced analysis tools SOFTWARE DEVELOPMENT KITS SDK CompuScope SDK for C C For Windows 98 ME NT 2...

Страница 13: ...1 003 GageScope Software Product Order No GageScope Lite Edition Included GageScope Standard Edition purchased with CompuScope hardware 300 100 351 GageScope Standard Edition purchased independently 3...

Страница 14: ...14 CompuScope 1220 CompuScope 1220 simplified block diagram Figure 1 CS1220 simplified block diagram...

Страница 15: ...ad of the CompuScope card s own oscillator External Trigger BNC Connector used to input an analog or digital signal which may be used as an External Trigger External Trigger is defined exactly as in a...

Страница 16: ...note that much higher PRFs will be achieved using CompuScope Multiple Record mode The following test results were obtained using a computer configured as follows Pentium III 1 GHz processor 512 MB RAM...

Страница 17: ...CompuScope 1220 17 Notes...

Отзывы: